GE Multilin
L30 Line Current Differential System
B-9
APPENDIX B
B.4 MEMORY MAPPING
B
B.4MEMORY MAPPING
B.4.1 MODBUS MEMORY MAP
Table B–9: MODBUS MEMORY MAP (Sheet 1 of 61)
ADDR
REGISTER NAME
RANGE
UNITS
STEP
FORMAT
DEFAULT
Product Information (Read Only)
0000
UR Product Type
0 to 65535
---
1
F001
0
0002
Product Version
0 to 655.35
---
0.01
F001
1
0003
Boot Configuration Register
0 to 65535
---
1
F001
0
Product Information (Read Only -- Written by Factory)
0010
Serial Number
---
---
---
F203
“0”
0020
Manufacturing Date
0 to 4294967295
---
1
F050
0
0022
Modification Number
0 to 65535
---
1
F001
0
0040
Order Code
---
---
---
F204
“Order Code x”
0090
Ethernet MAC Address
---
---
---
F072
0
0093
Reserved (13 items)
---
---
---
F001
0
00A0
CPU Module Serial Number
---
---
---
F203
(none)
00B0
CPU Supplier Serial Number
---
---
---
F203
(none)
00C0
Ethernet Sub Module Serial Number (8 items)
---
---
---
F203
(none)
Product Information (Read Only -- Written by Factory)
0110
FPGA Version
---
---
---
F206
(none)
0113
FPGA Date
0 to 4294967295
--
1
F050
0
Self Test Targets (Read Only)
0200
Self Test States (4 items)
0 to 4294967295
0
1
F143
0
Front Panel (Read Only)
0208
LED Column
n
State,
n
= 1 to 10 (10 items)
0 to 65535
---
1
F501
0
0220
Display Message
---
---
---
F204
(none)
0248
Last Key Pressed
0 to 47
---
1
F530
0 (None)
Keypress Emulation (Read/Write)
0280
Simulated keypress -- write zero before each keystroke
0 to 46
---
1
F190
0 (No key -- use
between real
keys)
Virtual Input Commands (Read/Write Command) (64 modules)
0400
Virtual Input 1 State
0 to 1
---
1
F108
0 (Off)
0401
Virtual Input 2 State
0 to 1
---
1
F108
0 (Off)
0402
Virtual Input 3 State
0 to 1
---
1
F108
0 (Off)
0403
Virtual Input 4 State
0 to 1
---
1
F108
0 (Off)
0404
Virtual Input 5 State
0 to 1
---
1
F108
0 (Off)
0405
Virtual Input 6 State
0 to 1
---
1
F108
0 (Off)
0406
Virtual Input 7 State
0 to 1
---
1
F108
0 (Off)
0407
Virtual Input 8 State
0 to 1
---
1
F108
0 (Off)
0408
Virtual Input 9 State
0 to 1
---
1
F108
0 (Off)
0409
Virtual Input 10 State
0 to 1
---
1
F108
0 (Off)
040A
Virtual Input 11 State
0 to 1
---
1
F108
0 (Off)
040B
Virtual Input 12 State
0 to 1
---
1
F108
0 (Off)
040C
Virtual Input 13 State
0 to 1
---
1
F108
0 (Off)
040D
Virtual Input 14 State
0 to 1
---
1
F108
0 (Off)
040E
Virtual Input 15 State
0 to 1
---
1
F108
0 (Off)
040F
Virtual Input 16 State
0 to 1
---
1
F108
0 (Off)
0410
Virtual Input 17 State
0 to 1
---
1
F108
0 (Off)
0411
Virtual Input 18 State
0 to 1
---
1
F108
0 (Off)
0412
Virtual Input 19 State
0 to 1
---
1
F108
0 (Off)
0413
Virtual Input 20 State
0 to 1
---
1
F108
0 (Off)
0414
Virtual Input 21 State
0 to 1
---
1
F108
0 (Off)
0415
Virtual Input 22 State
0 to 1
---
1
F108
0 (Off)
0416
Virtual Input 23 State
0 to 1
---
1
F108
0 (Off)
Summary of Contents for L30
Page 10: ...x L30 Line Current Differential System GE Multilin TABLE OF CONTENTS ...
Page 30: ...1 20 L30 Line Current Differential System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Page 370: ...5 244 L30 Line Current Differential System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Page 464: ...A 10 L30 Line Current Differential System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Page 600: ...C 30 L30 Line Current Differential System GE Multilin C 7 LOGICAL NODES APPENDIX C C ...
Page 610: ...D 10 L30 Line Current Differential System GE Multilin D 1 IEC 60870 5 104 APPENDIX D D ...
Page 622: ...E 12 L30 Line Current Differential System GE Multilin E 2 DNP POINT LISTS APPENDIX E E ...
Page 634: ...F 12 L30 Line Current Differential System GE Multilin F 3 WARRANTY APPENDIX F F ...
Page 644: ...x L30 Line Current Differential System GE Multilin INDEX ...