C.5 IEC 61850 IMPLEMENTATION VIA ENERVISTA UR SETUP
C
The
DataTypeTemplates
node defines instantiable logical node types. A logical node type is an instantiable template of the
data of a logical node. A
LnodeType
is referenced each time that this instantiable type is needed with an IED. A logical
node type template is built from DATA (DO) elements, which again have a DO type, which is derived from the DATA classes
(CDC). DOs consist of attributes (DA) or of elements of already defined DO types (SDO). The attribute (DA) has a func-
tional constraint, and can either have a basic type, be an enumeration, or a structure of a
DAType
. The DAType is built from
BDA elements, defining the structure elements, which again can be
BDA
elements of have a base type such as DA.
Figure C–5: ICD FILE STRUCTURE, DATATYPETEMPLATES NODE
842798A1.CDR
DataTypeTemplates
LNodeType (id, InClass)
DO (name, type)
Other LNodeType elements
Other DO elements
DOType (id, cdc)
DA (name, fc, bType, type)
Other DOType elements
Other DOType elements
Other DA elements
DAType (id)
BDA (name, bType, type)
Other DAType elements
Other DAType elements
Other BDA elements
Other BDA elements
EnumType (id)
EnumVal (ord)
Other EnumType elements
Other EnumVal elements
Text
Val
Text
SDO (name, type)
Other SDO elements
Summary of Contents for F60
Page 10: ...x F60 Feeder Protection System GE Multilin TABLE OF CONTENTS ...
Page 30: ...1 20 F60 Feeder Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Page 138: ...4 28 F60 Feeder Protection System GE Multilin 4 2 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Page 454: ...5 316 F60 Feeder Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Page 500: ...7 14 F60 Feeder Protection System GE Multilin 7 1 COMMANDS 7 COMMANDS AND TARGETS 7 ...
Page 508: ...8 8 F60 Feeder Protection System GE Multilin 8 2 FAULT LOCATOR 8 THEORY OF OPERATION 8 ...
Page 522: ...10 12 F60 Feeder Protection System GE Multilin 10 6 DISPOSAL 10 MAINTENANCE 10 ...
Page 660: ...B 116 F60 Feeder Protection System GE Multilin B 4 MEMORY MAPPING APPENDIX B B ...
Page 706: ...E 10 F60 Feeder Protection System GE Multilin E 1 IEC 60870 5 104 APPENDIX E E ...
Page 718: ...F 12 F60 Feeder Protection System GE Multilin F 2 DNP POINT LISTS APPENDIX F F ...
Page 728: ...H 8 F60 Feeder Protection System GE Multilin H 2 ABBREVIATIONS APPENDIX H H Z Impedance Zone ...
Page 730: ...H 10 F60 Feeder Protection System GE Multilin H 3 WARRANTY APPENDIX H H ...