CS250 User Manual
31
EN50131-1
EN50131-1 is a system security standard that enforces additional protection for the end user.
If EN50131-1 is on, the following security measures are enforced.
Generally, the installer code is disabled. Once enabled, entering the installer code gives the installer a choice of the installer menu or user menu.
If enabled, the installer code can be used as a user code to arm or disarm the system.
The installer code is disabled whenever a user code is entered, or a user arms the system.
The user must initiate all remote access. The installer cannot do so.
The system does not answer any incoming calls.
The installer cannot change the user or duress codes.
The entry time is limited to a maximum of 45 seconds.
The keypad does not continue to display the system state after it is armed.
The installer cannot clear the event log.
Turning EN50131 on and off
Turn EN50131-1 on by entering the super user code and selecting
User Menu - Users - Installr Access - Limit Access - Yes
.
Turn EN50131-1 off by entering the super user code and selecting
User Menu - Users - Installr Access - Limit Access
-