Kalatel CBR-PB3-WD 20 0150-0261A
7.
Section 4 contains all of the default Jumper Settings, if it is necessary
for you to manually configure the interface.
Troubleshooting Guide
Problem
Solution
Check to make sure the power transformer is plugged
in properly.
Red LED is not
illuminated
Replace power transformer.
Make sure the Triplex is showing the text box on
Monitor A.
Dip switch setting should be SW1: ON ON OFF ON
Check that the serial cable is plugged into Port
RS232/2 on the Triplex and Port 1 of the PB3 with the
RJ45 to RJ45 cable (4310-0034B).
Ensure the baud rate for Port 2 (RS232) on the Triplex
is set to 19200 bps.
Cannot display
demo text
Ensure camera addresses are set correctly.
Cannot connect
with HyperTerminal
Check cable connection.
Ensure the computers com port is enabled in the
system bios and Windows control panel.
Verify HyperTerminal’s communication settings are
19200, 8, N, 1, no flow control.