LOCATION 40 - SYSTEM TIMERS (10 segments, numerical data)
Location 40 contains the duration of various system timing functions. Example: If you desire the duration of the
Dynamic Battery Test to be 30 minutes, you should program [3]-[0]-[
r
] in segment 1 of this location. The [3]-[0] is the
number of minutes, and the [
r
] stores the data and moves to the next segment of this location.
Segment 1 - Dynamic Battery Test duration in minutes 0-255 minutes ("0" = no test)
Segment 2 - AC Fail report delay in minutes 0-255 minutes.
Segment 3 - Power Up Delay in seconds 0-60 seconds ("0" = no power up delay).
Segment 4 - Siren Time in minutes 1-255 minutes.
Segment 5 - Telephone Line Cut delay in seconds 0-255 seconds ("0" = no TLM).
Segment 6 - Cross Zone time in minutes 0-255 ("0" = no cross zoning).
Segment 7 - Chime time in 50 mS (1/20th second) increments from 0-12 seconds ("0" = follows zone 255 latched).
Segment 8 - Dial delay in seconds 0-255 seconds (“0 ” = no abort delay).
Segment 9 - Fire Alarm Verification time in seconds 120-255 seconds ("0" = no fire alarm verification). NOTE:
This feature is not approved for residential use in California
Segment 10 -Listen-In time in seconds 0-255 ("0" = no Listen-In time).
Note: The "Listen-In" feature cannot be enabled for UL Listed systems. The "Dynamic Battery Test" feature
cannot exceed four (4) hours. The dial delay shall be set to -0-.
LOCATION 41 - SPECIAL FEATURES (1 segment, feature selection data)
Segment 1:
1 -
On enables the 6-digit code option. If 6-digit option is enabled, all arm/disarm codes and the "Go To
Program Code" are 6 digits. If this option is enabled, the default user 1 code is [1]-[2]-[3]-[4]-[5]-[6].
NOTE: IF YOU ENABLE THIS OPTION, VERIFY THAT THE "GO TO PROGRAM CODE" IS A SIX-
DIGIT CODE BEFORE EXITING PROGRAMMING.
2 -
On requires code entry for [
r
]-[9]-[8] (perform call back download) and [
r
]-[9]-[9] (answer incoming call for
download) functions.
3 -
Enable Auto Cancel / Abort (Refer to feature definitions beginning on page 3)
4 -
Enable Walk-Test Mode (Refer to feature definitions beginning on page 3)
5-8
Reserved.
L
LOCATION 42 - GO TO PROGRAM CODE (6 segments, numerical data)
Location 42 contains the "Go To Program Code". This location contains either a 4 or 6-digit code. If the 6-digit code
option is enabled in Location 41, THIS CODE MUST CONTAIN SIX (6) DIGITS. If this option is not enabled in
location 41, the last 2 segments (digits) will be ignored. With the NX-8 disarmed, the "Go To Program Code" can be
used to enter the Program Mode.
LOCATION 43 - GO TO PROGRAM CODE PARTITION AND AUTHORIZATION (2 segments, feature selection)
The "Go To Program Code" can be used as a standard arm/disarm code. When using the code to arm or disarm, the
user ID is 255. (This code may not be changed in the Run Mode.)
Segment 1:
1 - Reserved.
2 - On enables "Go To Program Code" as an arm only code.
3 - On enables "Go To Program Code" as an arm only after closing.
4 - On enables "Go To Program Code" as a master arm/disarm code (can change user codes)
5 - On enables "Go To Program Code" as an arm/disarm code.
6 - On enables "Go To Program Code" to bypass zones.
7 - On enables "Go To Program Code" opening and closing reports.
8 - Reserved.
Segment 2:
1 - On enables the "Go To Program Code" for Partition #1.
2 - On enables the "Go To Program Code" for Partition #2.
3 - On enables the "Go To Program Code" for Partition #3.
4 - On enables the "Go To Program Code" for Partition #4.
5 - On enables the "Go To Program Code" for Partition #5.
6 - On enables the "Go To Program Code" for Partition #6.
7 - On enables the "Go To Program Code" for Partition #7.
8 - On enables the "Go To Program Code" for Partition #8.
L