Page 39
LOC
PG
DESCRIPTION
DEFAULT
PROGRAMMING DATA
L
19
16
DOWNLOAD ACCESS CODE
8-4-8-0-0-0-0-0
_ _ _ _ _ _ _ _
L
20
16
RINGS TO ANSWER DOWNLOAD
8
_
DOWNLOAD CONTROL
Segment #1 (Circle Numbers To Program)
L
21
16
1
2
3
4
5
6
7
8
Enables two call answering machine defeat
Enables tone sniff answering machine defeat
Requires callback before downloading
Shutdown control panel
Lock out local programming
Lock out communicator programming
Lock out download section
Enables callback at autotest interval
L
22
16 CALLBACK PHONE NUMBER
14-14-14-14-14-14-14-14-14-14-
14-14-14-14-14-14-14-14-14-14
__ __ __ __ __ __ __ __ __ __
__ __ __ __ __ __ __ __ __ __
PARTITION #1, FEATURE SELECTION
L
23
17
Segment #1
Segment #2
Segment #3
1
2
3
4
5
6
7
8
Quick Arm
Re-Exit
Auto Bypass
Silent Panic
Audible Panic
Auxiliary 1
Auxiliary 2
Multi Keypress Tamper
1
2
3
4
5
6
7
8
LED extinguish enable
Require user code for bypassing zones
Bypass sounder alert
AC power/low battery sounder alert
Enables bypass toggle
Enables silent auto arm
Enables automatic instant
Reserved
1
2
3
4
5
6
7
8
Open/Close
Bypass
Restore
Trouble
Tamper
Cancel
Recent Closing
Exit Error
ENTRY/EXIT TIMERS
Segment #1 (Entry Time #1)
30
Segment #2 (Exit Time #1)
60
Segment #3 (Entry Time #2)
30
L
24
17
Segment #4 (Exit Time #2)
60
L
25
19
ZONES 1-8, ZONE TYPES
3-5-6-6-6-6-6-6
_ _ _ _ _ _ _ _
ZONES 1-8, PARTITION SELECTION (Segment 1=Zone 1 thru Segment 8=Zone 8)
Segments
1
2
3
4
5
6
7
8
26
19
Partition #1
Partition #2
Partition #3
Partition #4
Partition #5
Partition #6
Partition #7
Partition #8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8