Page 52
APPENDIX 2 REPORTING ZONE CODES IN SIA OR CONTACT ID
The NX-8 has the ability to report SIA level 1 transmissions to either or both phone numbers. Each report in SIA
consists of an Event Code and a Zone or User ID. The Zone ID will be the zone number that is in alarm. The event
code will come from the chart below and be programmed in the zone type event code.
Programmed Event Code
SIA Code
Description
0
HA
Holdup Alarm
1
FA
Fire Alarm
2
PA
Panic alarm
3
BA
Burglary Alarm
4
BA
Burglary Alarm
5
BA
Burglary Alarm
6
UA
Untyped Alarm
7
BA
Burglary Alarm
8
BA
Burglary Alarm
9
UA
Untyped Alarm
10
HA
Holdup Alarm
11
MA
Medical Alarm
12
PA
Panic alarm
13
TA
Tamper Alarm
14
RP
Periodic Test
15
GA
Gas Alarm
16
KA
Heat Alarm
17
WA
Water Alarm
18
QA
Emergency Alarm
19
SA
Sprinkler Alarm
20
ZA
Freeze Alarm
The NX-8 has the ability to report Ademco Contact ID transmissions. Each report in Contact ID consists of an Event
Code and a Zone ID. The zone ID is the zone that created the alarm. The event code will come from the chart below
and be programmed in the zone type event code.
Programmed Event Code
Contact ID Code
Description
0
122
Silent Panic
1
110
Fire Alarm
2
120
Panic alarm
3
130
Burglary Alarm
4
131
Perimeter Alarm
5
132
Interior Alarm
6
133
24 Hour Burglary
7
134
Entry Alarm
8
135
Day/Night Alarm
9
150
Non Burglary 24 Hour
10
121
Duress Alarm
11
100
Medical Alarm
12
123
Audible Panic Alarm
13
137
Tamper Alarm
14
602
Periodic Test
15
151
Gas Detected
16
158
High Temp
17
154
Water Leakage
18
140
General Alarm
19
140
General Alarm
20
159
Low Temp