0150-0193C
38
Calibur DVMR
e
Triplex
q
Main Menu
→
Alarms
→
Alarm Action
This menu is not available on 4-channel units. Only the full screen alarm
display is available on the 4-channel unit. Therefore, a 4 channel unit will
always be limited to the default values in this menu, i.e. no presets linked
to alarms and alarm relay is always Relay 1.
Input:
Select the input you wish to configure.
Freeze:
Selecting
Yes
will freeze the alarm camera display (quadrant 1)
at the time the alarm is activated.
Cameras:
This setting determines the four cameras displayed on-screen
when an alarm is received. The camera group contains the camera in alarm
and three associated cameras.
Default Settings:
The first camera in the list is the camera in alarm. The second
camera in the list is the camera that precedes the alarm camera numerically.
The third and fourth cameras in the list are the two cameras following the
alarm camera numerically.
Preset:
Use this feature to send a camera to a preset when an alarm is
activated. The preset number corresponds directly with the camera number located directly above it in
this menu. Select from 1 through 16. If this field is left blank, the camera will not respond. In the
example above, Camera 1 will go to Preset 1, while Camera 2 will go to Preset 9.
Relay:
Configure which relay will be triggered when an alarm is activated per camera. Select from:
•
1
•
2
•
1 + 2
•
None
Rotate the
Jog
to navigate and the
Shuttle
to change the values.
q
Main Menu
→
Alarms
→
Alarm Record Mode
Use this menu to determine how the unit will record cameras in alarm.
No Change:
Unit changes to the Alarm Record Rate, but it does not
give priority to the camera in alarm.
Exclusive:
The unit records only the camera (or cameras) in alarm.
Interleaved:
Alarmed cameras are recorded at a higher rate than
non-alarm cameras. The unit accomplishes this by interleaving images
of alarmed cameras between images from non-alarmed cameras in the record list.
Interleaved is the
recommended mode of operation.
Example of Record Lists:
No Change record list for 8 cameras, Camera-4 in alarm.
1 2 3
4
5 6 7 8 1 2 3
4
5 6 7 8
Exclusive record list for 8 cameras, Camera-4 in alarm.
4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4
Interleaved record list for 8 cameras, Camera-4 in alarm.
1
4
2
4
3
4
5
4
6
4
7
4
8
4
1
4
q
Main Menu
→
Alarms
→
Enable / Disable
Use this menu to Enable or Disable the alarm inputs.
Select from the following:
Alarm Action Setup
Input :
Freeze : Yes
Cameras: 01 16 02 03
Presets: 01 -- 09 --
Relay : 1
01
[CANCEL] [OK]
Alarm Record Mode
Interleaved
Select Mode
Enable All
Disable All
Individual Enable