90
Mercury Reference Manual
05-4446A01, Rev. E
Figure 3-55. Modbus/TCP Server Listening Port
4. On the next screen (
Figure 3-56
), press
A
to change the Modbus
serial format, then press the space bar to toggle between the avail-
able formats (
MODBUS/RTU
or
MODBUS/ASCII
). Press
B
to enter the
Modbus serial timeout value in milliseconds. Press
N
to continue the
wizard.
NOTE:
The only difference between Modbus/RTU and
Modbus/ASCII is the form of the framing sequence, error
check pattern, and address interpretation.
Figure 3-56. Choose Modbus Serial Format and Timeout Value
Note: Modbus Timeout setting is in milliseconds, not seconds
as displayed in the example above.