1–8
345 TRANSFORMER PROTECTION SYSTEM – INSTRUCTION MANUAL
345 ORDER CODES
CHAPTER 1: INTRODUCTION
Empty chassis
The 345 protection relay chassis used with a drawout relay is available separately, for use
as a partial replacement or in test environments. Many features are supported by the
cards and ports within the chassis, as is reflected in the chassis order code.
NOTE
NOTE:
The chassis order code and drawout relay order code must match exactly.
FASTPATH:
A drawout relay cannot be used in a chassis with different order code options.
Figure 1-4: 350 chassis order codes
Remote Module I/O
The remote RTD Module provides additional protection by monitoring the temperature of
key components in the equipment.
Accessories
•
18L0-0075 3 Series Depth reducing collar - 1.375”
•
18L0-0076 3 Series Depth reducing collar - 3.00”
•
18L0-0080 3 Series IP20 Kit
•
3S-NDO-STCONKIT 3 Series NDO straight terminal block kit
•
0804-0458 USB A-B configuration cable - 6’
897800CH-A1.PDF
345
CH *
*
*
N
N
*
*
*
Phase Currents
P1
|
|
|
|
1 A 3-phase CTs (Winding 1 - 1 A, Winding 2 - 1 A)
P5
|
|
|
|
5 A 3-phase CTs (Winding 1 - 5 A, Winding 2 - 5 A)
Ground Currents
a
a Ground current options G1/G5 must match the corresponding P1/P5 Phase currents
G1
|
|
|
1 A standard ground CTs (Winding 1 - 1 A, Winding 2 - 1 A)
G5
|
|
|
5 A standard ground CTs (Winding 1 - 5 A, Winding 2 - 5 A)
S1
|
|
|
1 A sensitive ground CTs (Winding 1 - 1 A, Winding 2 - 1 A)
S5
|
|
|
5 A sensitive ground CTs (Winding 1 - 5 A, Winding 2 - 5 A)
Communications
S
N
|
|
Standard: Front USB, Rear RS485: Modbus RTU, DNP3.0,
IEC60870-5-103
1
E
|
|
St Ethernet (Copper & Fiber - MTRJ),
Modbus TCP/IP, DNP3.0, IEC 60870-5-104
2
E
|
|
St Ethernet (Copper & Fiber - MTRJ),
Modbus TCP/IP, DNP3.0, IEC 60870-5-104, IEC 61850 GOOSE
3
E
|
|
St Ethernet (Copper & Fiber - MTRJ),
Modbus TCP/IP, DNP3.0, IEC 60870-5-104, IEC 61850
Harsh Environment
N
None
H
Harsh Environment Conformal Coating
897800RMIO-A1.fm
RMIO *
G
G
*
*
Power Supply
L
|
|
|
|
24 - 48 V DC
H
|
|
|
|
110 - 250 V DC / 110 - 230 V AC
I/O Module 1
G
|
|
|
Remote Module I/O (3 - 100 Ohm Platinum RTDs)
I/O Module 2
G
|
|
Remote Module I/O (3 - 100 Ohm Platinum RTDs)
I/O Module 3
G
|
Remote Module I/O (3 - 100 Ohm Platinum RTDs)
X
|
None
I/O Module 4
G
Remote Module I/O (3 - 100 Ohm Platinum RTDs)
X
None