FEATURE INFORMATION
565/575 MEMORY MAP (REVISION E2.73)
ADDRESS
GROUP
DESCRIPTION
RANGE
STEP
UNITS
SCALE
FORMAT
FACTORY
(DEC) (HEX)
CODE
DEFAULT
Actual Values - READ ONLY
0444
01BC
SWITCH NUMBER 4 STATUS
0 or 1
-
-
-
F28
0
0471
01D7
SWITCH NUMBER 5 STATUS
0 or 1
-
-
-
F28
0
0472
01D8
SWITCH NUMBER 6 STATUS
0 or 1
-
-
-
F28
0
0473
01D9
SWITCH NUMBER 7 STATUS
0 or 1
-
-
-
F28
0
0474
01DA
SWITCH NUMBER 8 STATUS
0 or 1
-
-
-
F28
0
0445
01BD
BREAKER OPEN STATUS
0 or 1
-
-
-
F37
0
0446
01BE
BREAKER CLOSED STATUS
0 or 1
-
-
-
F37
0
0447
01BF
ANALOG SELECT A STATUS
0 or 1
-
-
-
F38
0
0448
01C0
ANALOG SELECT B STATUS
0 or 1
-
-
-
F38
0
0449
01C1
ANALOG SELECT C STATUS
0 or 1
-
-
-
F38
0
0450
01C2
ANALOG SELECT D STATUS
0 or 1
-
-
-
F38
0
0451
01C3
ACCESS JUMPER STATUS
0 or 1
-
-
-
F20
1
0452
01C4
REMOTE/LOCAL 43 STATUS
0 or 1
-
-
-
F39
0
0453
01C5
RESERVED
:
:
:
0454
01C6
RESERVED
0455
01C7
(575 Only)
RECLOSE ENABLE STATUS
0 or 1
-
-
-
F37
0
0456
01C8
(575 Only)
RECLOSE DISABLE STATUS
0 or 1
-
-
-
F37
1
0457
01C9
RESERVED
:
:
:
0459
01CB
RESERVED
0460
01CC
LCD DISPLAY CONTRAST
0 - 10
1
-
1.00
F14
5
0461
01CD
SOFTWARE RELEASE DATE
-
-
-
-
F13
Mar 12, 1996
0463
01CF
RESERVED
0464
01D0 FACTORY SERVICE ANALOG OUTPUT FORCED TO
0 - 255
1
-
1.00
F14
0
0465
01D1
RESERVED
0466
01D2
TEST LCD DISPLAY? (RESERVED)
0467
01D3
RESERVED
0468
01D4
LOAD FACTORY SETTINGS (RESERVED)
0469
01D5
CAL. ANALOG IN AT 4 mA (RESERVED)
0470
01D6
CAL. ANALOG IN AT 20 mA (RESERVED)
0471
01D7
SEE SETPOINTS CALIBRATION MODE GROUP
:
:
:
0474
01DA
SEE SETPOINTS CALIBRATION MODE GROUP
0475
01DB
RESERVED
:
:
:
0489
01E9
RESERVED
0490
01EA
VOLTAGE
VT CONNECTION
0 - 3
-
-
-
F40
1
0491
01EB
VT NOMINAL SEC VOLTS
48.0 - 240.0
0.1
VOLTS
0.10
F14
120.0
0492
01EC
VT PRIMARY VOLTS
0.10 - 138.00
0.01
kV
0.01
F14
1.20
0615
0267
ZERO VOLTS DETECT
0 or 1
-
-
-
F20
1
0493
01ED
UNDERVOLT TRIP
0 or 1
-
-
-
F20
1
0494
01EE
UNDERVOLT TRIP LEVEL
50 - 100
1
%VT
1.00
F14
80
0495
01EF
UNDERVOLT TRIP DELAY
0.1 - 25.5
0.1
SEC
0.10
F14
1.0
0496
01F0
UNDERVOLT TRIP RELAY
0 - 6
-
-
-
F22
3 (565), 1 (575)
0497
01F1
UNDERVOLT ALARM
0 or 1
-
-
-
F20
1
0498
01F2
UNDERVOLT ALARM LEVEL
50 - 100
1
%VT
1.00
F14
85
0499
01F3
UNDERVOLT ALARM DELAY
0.1 - 25.5
0.1
SEC
0.10
F14
1.0
0500
01F4
UNDERVOLT ALARM RELAY
0 - 3
-
-
-
F23
1 (565), 2 (575)
0501
01F5
OVERVOLT TRIP
0 or 1
-
-
-
F20
1
0502
01F6
OVERVOLT TRIP LEVEL
101 - 125
1
%VT
1.00
F14
120
0503
01F7
OVERVOLT TRIP DELAY
0.1 - 25.5
0.1
SEC
0.10
F14
1.0
0504
01F8
OVERVOLT TRIP RELAY
0 - 6
-
-
-
F22
0 (565), 1 (575)
0505
01F9
OVERVOLT ALARM
0 or 1
-
-
-
F20
1
0506
01FA
OVERVOLT ALARM LEVEL
101 - 125
1
%VT
1.00
F14
115
0507
01FB
OVERVOLT ALARM DELAY
0.1 - 25.5
0.1
SEC
0.10
F14
1.0
0508
01FC
OVERVOLT ALARM RELAY
0 - 3
-
-
-
F23
0
0509
01FD
RESERVED
:
:
:
0519
0207
RESERVED
0520
0208 DEMAND METERING AMPS DEMAND
0 or 1
-
-
-
F20
0
0521
0209
AMPS DEMAND TIME PERIOD
5 - 120
1
MIN
1.00
F14
5
0522
020A
AMPS DEMAND ALARM
0 or 1
-
-
-
F20
1
0523
020B
AMP DEMAND ALARM LEVEL
10 - 5000
5
AMPS
1.00
F14
100
0524
020C
AMP DEMAND ALARM RELAY
0 - 3
-
-
-
F23
0 (565), 2 (575)
0525
020D
KW DEMAND
0 or 1
-
-
-
F20
0
0526
020E
KW DEMAND TIME PERIOD
5 - 120
1
MIN
1.00
F14
5
0527
020F
KW DEMAND ALARM
0 or 1
-
-
-
F20
1
0528
0210
KW DEMAND ALARM LEVEL
100 - 65000
100
kW
1.00
F14
1000
0529
0211
KW DEMAND ALARM RELAY
0 - 3
-
-
-
F23
0 (565), 2 (575)
0530
0212
KVAR DEMAND
0 or 1
-
-
-
F20
0
6-15
Summary of Contents for 565
Page 6: ...INSTALLATION 2 2 Figure 2 1 Mounting Details ...
Page 7: ...INSTALLATION 2 3 Figure 2 2 Mounting Arrangement with Relay Collar ...
Page 12: ...INSTALLATION 2 8 Figure 2 5 565 Relay Typical Wiring ...
Page 13: ...INSTALLATION 2 9 Figure 2 6 Voltage Sensing Wire ...
Page 14: ...INSTALLATION 2 10 Figure 2 7A 565 with MTM CT and Open Delta VT Typical Wiring ...
Page 15: ...INSTALLATION 2 11 Figure 2 7B 565 with MTM CT and Wye VT Typical Wiring ...
Page 16: ...INSTALLATION 2 12 Figure 2 8A Open Delta VT and CT MTM Typical Wiring ...
Page 17: ...INSTALLATION 2 13 Figure 2 8B Wye VT and CT MTM Typical Wiring ...
Page 18: ...INSTALLATION 2 14 Figure 2 9 MTM Mounting Dimensions ...
Page 19: ...INSTALLATION 2 15 Figure 2 10 565 Rear Panel Layout ...
Page 20: ......
Page 23: ...DISPLAY AND KEYBOARD 3 3 Figure 4 1 565 Relay Front Panel ...
Page 28: ......
Page 132: ......
Page 142: ...CURVE INFORMATION ANDTABLES 7 10 Figure 7 9 IEC A Curves ...
Page 143: ...CURVE INFORMATION ANDTABLES 7 11 Figure 7 10 IEC B Curves ...
Page 144: ...CURVE INFORMATION ANDTABLES 7 12 Figure 7 11 IEC C Curves ...
Page 176: ...RELAYTESTING 8 2 Figure 8 1 Secondary Injection Test Setup ...
Page 180: ......
Page 184: ......
Page 192: ...APPENDIX C C 2 Figure C1 System Controller Block Diagram 1 2 ...
Page 193: ...APPENDIX C C 3 Figure C2 System Controller Block Diagram 2 2 ...
Page 194: ......