SETPOINTS MODE
5-3
1.
User Level setpoints.
User level
Security Feature/Access code
2.
Phase Current setpoints.
Phase CT primary rating
Phase overcurrent pickup level
Phase overcurrent curve shape
Phase overcurrent time dial
Phase overcurrent trip relay
Phase overcurrent alarm
Phase instantaneous trip (565 only)
Phase custom curve trip times (565 only)
Phase HISET instantaneous trip (575 only)
Phase autoblock HISET (575 only)
Phase LOSET instantaneous trip (575 only)
Phase custom curves 1 trip times (575 only)
3.
Ground Current setpoints.
Ground sensing system
Ground CT primary rating
Ground overcurrent pickup level
Ground overcurrent curve shape (565 only)
Ground overcurrent curve 1 shape (575 only)
Ground overcurrent time dial (565 only)
Ground overcurrent time dial 1 (575 only)
Ground overcurrent trip relay
Ground overcurrent alarm
Ground instantaneous trip (565 only)
Ground HISET instantaneous trip (575 only)
Ground autoblock HISET (575 only)
Ground LOSET instantaneous trip (575 only)
Ground autoblock LOSET (575 only)
Ground custom curve trip times
Ground custom curve 1 trip times (575 only)
4.
Configuration Setpoints.
Clock
Switch contact functions
Switch contact configurations
Relay assignments
Breaker response delay
Breaker discrepancy delay
Trip coil supervision
Accumulated KA
Event recording
Event printing
Cold load P/U delay
MTM communications enable
Summary of Setpoint Page Contents
Page
Contents
Page
Contents
5.
Analog Input setpoints.
Analog input title and units
Min and max current scale values
Analog input trip
Analog input alarm
6.
Analog Output setpoints.
Analog output parameters
Analog output range
7.
Communications setpoints.
Relay address
Baud rate
8.
Calibration Mode setpoints.
Exercise relay
Status of switch inputs
LCD display contrast
Multilin 565 Relay Revision
9.
Voltage setpoints.
VT connection
VT nominal secondary volts
VT primary volts
Zero volts detect
Undervoltage trip
Undervoltage alarm
Overvoltage trip
Overvoltage alarm
10.
Demand Metering setpoints.
Amps demand
KW demand
KVAR demand
Summary of Contents for 565
Page 6: ...INSTALLATION 2 2 Figure 2 1 Mounting Details ...
Page 7: ...INSTALLATION 2 3 Figure 2 2 Mounting Arrangement with Relay Collar ...
Page 12: ...INSTALLATION 2 8 Figure 2 5 565 Relay Typical Wiring ...
Page 13: ...INSTALLATION 2 9 Figure 2 6 Voltage Sensing Wire ...
Page 14: ...INSTALLATION 2 10 Figure 2 7A 565 with MTM CT and Open Delta VT Typical Wiring ...
Page 15: ...INSTALLATION 2 11 Figure 2 7B 565 with MTM CT and Wye VT Typical Wiring ...
Page 16: ...INSTALLATION 2 12 Figure 2 8A Open Delta VT and CT MTM Typical Wiring ...
Page 17: ...INSTALLATION 2 13 Figure 2 8B Wye VT and CT MTM Typical Wiring ...
Page 18: ...INSTALLATION 2 14 Figure 2 9 MTM Mounting Dimensions ...
Page 19: ...INSTALLATION 2 15 Figure 2 10 565 Rear Panel Layout ...
Page 20: ......
Page 23: ...DISPLAY AND KEYBOARD 3 3 Figure 4 1 565 Relay Front Panel ...
Page 28: ......
Page 132: ......
Page 142: ...CURVE INFORMATION ANDTABLES 7 10 Figure 7 9 IEC A Curves ...
Page 143: ...CURVE INFORMATION ANDTABLES 7 11 Figure 7 10 IEC B Curves ...
Page 144: ...CURVE INFORMATION ANDTABLES 7 12 Figure 7 11 IEC C Curves ...
Page 176: ...RELAYTESTING 8 2 Figure 8 1 Secondary Injection Test Setup ...
Page 180: ......
Page 184: ......
Page 192: ...APPENDIX C C 2 Figure C1 System Controller Block Diagram 1 2 ...
Page 193: ...APPENDIX C C 3 Figure C2 System Controller Block Diagram 2 2 ...
Page 194: ......
Page 198: ......