Quick Start Guide

Commonly used tools
- Phillips head screwdriver
- Flat head screwdriver
- Hammer
- Wire cutter/stripper

Supplied hardware
- #10 Screw (3)
- #10 Drywall anchors

MIN. COPPER WIRE 

SIZE (AWG)

MAX LOAD 

(AMP)

MINIMUM INSULATION 

TEMP (°C)

PRESSURE PLATE
TERMINAL SCREW
MAKE SURE WIRE 
INSULATION CLEARS 
PRESSURE PLATE

14

15

60

12

20

60

10

30

60

8

40

105

USE CORRECT GAUGE WIRE PER LOCAL ELECTRICAL CODE

• RECOMMENDED INSTALLATION BY LICENSED ELECTRICIAN.
• HIGH VOLTAGE (THERE MAY BE MORE THAT ONE SOURCE OF SUPPLY) 

DISCONNECT ALL POWER SOURCES BEFORE SERVICING.

• RISK OF ELECTRIC SHOCK – ALL TERMINALS ARE LIVE.
• USE COPPER WIRE ONLY.
• CLOSE THE COVER AFTER SETTING.
• TIGHTEN CONNECTIONS TO 25 LBF-IN.
• USE CORRECT GAUGE WIRE (8-14 AWG) BASED ON LOCAL ELECTRICAL 

CODE OF AT LEAST 105C RATING.

• APPROVED FOR OUTDOOR USE.
• WIRE STRIP LENGTH ½”
• GROUNDING: NATIONAL ELECTRICAL CODE REQUIRES THAT GROUNDING 

MUST BE CONTINUOUS AND IN PROPER ELECTRICAL CONTACT IN ALL 
GROUNDING CONDUCTORS, METALLIC CONDUITS AND GROUNDING 
TERMINALS.

 

WARNING

Summary of Contents for 15163

Page 1: ...ENDED INSTALLATION BY LICENSED ELECTRICIAN HIGH VOLTAGE THERE MAY BE MORE THAT ONE SOURCE OF SUPPLY DISCONNECT ALL POWER SOURCES BEFORE SERVICING RISK OF ELECTRIC SHOCK ALL TERMINALS ARE LIVE USE COPP...

Page 2: ...the pictures below to remove knockouts For knockout place small blade screw driver as pictured above Tap lightly to punch knockout loose For knockout first use screwdriver to punchout knockout then u...

Page 3: ...ce 3 If mounting to drywall a Drill a 3 16 size hole for the drywall anchors at the marked locations b Insert an anchor in each hole then gently tap the open end of anchor with a hammer until the anch...

Page 4: ...MORE THAT ONE SOURCE OF SUPPLY DISCONNECT ALL POWER SOURCES BEFORE SERVICING RISK OF ELECTRIC SHOCK ALL TERMINALS ARE LIVE USE COPPER WIRE ONLY CLOSE THE COVER AFTER SETTING TIGHTEN CONNECTIONS TO 25...

Page 5: ...eep to the side Step 2 Connect the Input Clock Motor Voltage 1 Connect 120VAC Hot Black to Terminal L Do not remove the jumper connecting Terminals L and 1 2 Connect 120VAC Neutral White to terminal X...

Page 6: ...AC Neutral of the Load White to terminal X 3 Connect the bare wire to the ground lug Tighten the screw terminals to 25in lb Improper tightening can cause heating and equipment failure Step 4 Reinstall...

Page 7: ...dial turning Wait at least 30 minutes after the set ON or OFF time to verify the timer is operating properly Step 6 Check timer after 24 hours 1 After 24 hours remove power from the timer and check t...

Page 8: ...side connections It snaps easily in and out of place If the guard has come off during shipment or installation reinstall by placing the two tabs at the bottom in the appropriate slots Plastic guard f...