23
fuel conversion
The engine of your generator system is factory calibrated to
run on natural gas (NG) or on liquefied petroleum (LP) vapor.
To convert to either fuel, follow these steps:
NOTICE
Units are set to NG at the factory.
1. Insert key into lock of front panel. Gently push down
on roof above the lock to aid in turning the key. Turn
key one quarter turn clockwise.
2. Lift roof to the open position.
3. Press the control board OFF button.
4. Remove 15 Amp fuse from control panel.
5. Remove the rear panel.
a
6. Locate the fuel selector switch (A). located on top of
the fuel regulator (B.Using a 5 mm Allen wrench,
turn the selector switch to either LP or NG.
7. Reinstall the rear panel.
8. Reinstall 15 Amp fuse in control panel.
9. Press the control board AUTO
button.
a
B
B
NOT
for
REPRODUCTION