background image

For models equipped with power cord: 

Do not modify the plug 

provided with the appliance; if it will not fit the outlet, have a 
proper outlet installed by a qualified technician.

Cabinet Preparation & Wire Routing

• The wiring may enter the opening from either side, rear or the 

floor within the shaded area illustrated above in Figure E and 
defined in Figure A.

• Cut a 1-1/2" maximum diameter hole to admit the electrical 

cable. Permanent wiring connections may pass through the 
same hole as the drain hose and hot water line, if convenient. 
If cabinet wall is metal, the hole edge must be covered with a 
bushing. 

NOTE:

 Power cords with plug must pass through a separate 

hole. 

Electrical Connection to Dishwasher

Electrical connection is on the right front of dishwasher.
• For permanent connections the cable must be routed as 

shown in Figure E. Cable must extend a minimum of 24" from 
the rear wall.

• For power cord connections, install a 3-prong grounding 

type receptacle in the sink cabinet rear wall, 6" min. or 18" 
maximum from the opening, 6" to 18" above the floor. 

PREPARE ELECTRICAL WIRING

Electrical Requirements

• This appliance must be supplied with 120V, 60 Hz., and   

connected to an individual properly grounded branch circuit, 
protected by a 15- or 20-ampere circuit breaker or time-
delay fuse.

• Wiring must be 2 wire with ground and rated for 75°C (176°F).
• If the electrical supply does not meet the above  requirements, 

call a licensed electrician before  proceeding.

Grounding Instructions–Permanent Connection

This appliance must be connected to a grounded metal, 
permanent wiring system, or an equipment-grounding 
conductor must be run with the circuit conductors and be 
connected to the equipment-grounding terminal or lead on 
the appliance.

Grounding Instructions–Power Cord Models

This appliance must be grounded. In the event of a malfunction 
or breakdown, grounding will reduce the risk of electric shock 
by providing a path of least resistance for electric current. 
This appliance is equipped with a cord having an equipment-
grounding conductor and a grounding plug. The plug must 
be plugged into an appropriate outlet that is installed and 
grounded in accordance with all local codes and ordinances.

White

18"

6"

24"

from Wall

3"

from

Cabinet

Alternate
Receptacle
Location

Ground

Black

1-1/2" Dia. Hole (Max.)

18"

6"

Receptacle
Location
Area

Figure E

Installation Preparation

4

WARNING:

FOR PERSONAL SAFETY: Remove house fuse or open circuit breaker 
before beginning installation. Do not use an extension cord or 
adapter plug with this appliance.

 ADVERTENCIA:

PARA SEGURIDAD PERSONAL: Quite el fusible o abra el interruptor 
de circuitos antes de comenzar la instalación. No utilice un cable 
de extensión o un enchufe adaptador con este artefacto.

WARNING:

The improper connection of the equipment grounding conductor 
can result in a risk of electric shock. Check with a qualifi ed 
electrician or service representative if you are in doubt that 
the appliance is properly grounded.

 ADVERTENCIA:

La conexión inadecuada del conductor de conexión a tierra del 
equipamiento puede provocar un riesgo de descarga eléctrica.  
Consulte a un electricista califi cado o representante de servicio 
técnico si tiene dudas sobre la correcta conexión a tierra del aparato.

Summary of Contents for 206C1559P197

Page 1: ...nstallations described in this booklet gloves safety glasses or goggles should be worn READ CAREFULLY KEEP THESE INSTRUCTIONS IMPORTANT Observe all governing codes and ordinances Note to Installer Be sure to leave these instructions for the consumer s and local inspector s use Note to Consumer Keep these instructions with your Owner s Manual for future reference Skill Level Installation of this di...

Page 2: ...in hose approximately 78 long Zip ties Side and top trim pieces some models Literature samples and or coupons 2 Side mounting brackets with four 8 pan head mounting screws for non wood countertops some models MATERIALS YOU WILL NEED Ferrule compression nut and 90 elbow 3 8 NPT external thread on one end opposite end sized to fit water supply Thread seal tape UL listed wire nuts 3 GPF65 side mount ...

Page 3: ...e smooth with no sharp edges IMPORTANT When connecting drain line to disposer check to be sure that drain plug has been removed DISHWASHER WILL NOT DRAIN IF PLUG IS LEFT IN PLACE Method 2 High Drain Loop with Waste Tee or Disposer Tip Avoid unnecessary service call charges Always be sure disposer drain plug has been removed before attaching dishwasher drain hose to the disposer Figure D The dishwa...

Page 4: ...t be connected to a grounded metal permanent wiring system or an equipment grounding conductor must be run with the circuit conductors and be connected to the equipment grounding terminal or lead on the appliance Grounding Instructions Power Cord Models This appliance must be grounded In the event of a malfunction or breakdown grounding will reduce the risk of electric shock by providing a path of...

Page 5: ...in an accessible location such as under the sink Optional but strongly recommended and may be required by local codes Water connection is on the left side of the dishwasher Install the hot water inlet line using no less than 3 8 copper tubing Route the line as shown in Figure F and extend forward at least 19 from rear wall Adjust water heater for 120 F to 150 F temperature Flush water line to clea...

Page 6: ...open easily or falls too quickly check spring cable routing The cable is held in place by shoulders on the pulley Check to be sure cable has not slipped over the pulley shoulders Increase Spring Tension Decrease Spring Tension Correct Incorrect Insert Hook Over Bracket STEP 1 PREPARATION Locate the items in the installation package and set aside for use in the listed steps Screw kit Steps 5 or 18 ...

Page 7: ...requirements Install strain relief in junction box bracket Insert power cord through strain relief and tighten Make sure black white and green dishwasher wires are threaded through small hole in junction box bracket Connect power cord white or ribbed to dishwasher white wire black or smooth to dishwasher black wire and ground to dishwasher green wire Use UL listed wire nuts of appropriate size Ins...

Page 8: ...l occur Grasp the sides of the front panel and slide dishwasher into the opening a few inches at a time As you proceed pull the drain hose through the opening under the sink Stop pushing when the dishwasher extends about 6 inches forward of adjacent cabinets Make sure drain hose is not kinked under or behind the dishwasher Make certain the house wiring drain line and water line do not interfere wi...

Page 9: ...tion STEP 12 INSTALL GPF65 SIDE MOUNT BRACKETS Skip this step if underside of countertop is wood or wood like material In this step you will need the side mount kit you set aside in Step 1 Install side mount brackets if underside of countertop is granite or similar material that will not accept wood screws Fasten the left hand bracket to the left side of the dishwasher frame and the right hand bra...

Page 10: ...et aside in Step 1 The dishwasher must be secured to the countertop or the cabinet sides When the underside of the countertop is wood use Method 1 Use Method 2 when the underside of the countertop is made of a material such as granite that will not accept wood screws IMPORTANT Prevent door panel and control panel damage Dishwasher must be positioned so the front panel and control panel do not cont...

Page 11: ... of 120 10 feet to the factory installed hose Use 5 8 or 7 8 inside diameter hose and a coupler to connect the two hose ends Secure the connection with hose clamps Figure W Figure X NOTE TOTAL DRAIN HOSE LENGTH MUST NOT EXCEED 10 FEET FOR PROPER DRAIN OPERATION 7 bT 2 P _ 2 d_ Ta 7 bT 2 P _ Remove Drain Plug Tip Avoid unnecessary service call charges for a no drain complaint Make sure excess drain...

Page 12: ...water faucet and verify water temperature Incoming water temperature must be between 120 F and 150 F A minimum of 120 F temperature is required for best wash performance See Prepare Hot Water Line page 5 Add 2 quarts of water to the bottom of the dishwasher to lubricate the pump seal Turn on water supply Check for leaks Tighten connections if needed Remove protective film if present from the contr...

Page 13: ...ff power at the breaker and correct plumbing as necessary Restore power after corrections are made See Steps 7 and 17 Open dishwasher door and make sure most of the water has drained If not check that disposer plug has been removed and or air gap is not plugged Also check drain hose to be sure it is not kinked underneath or behind dishwasher See Step 17 Press Start Reset pad once again and run dis...

Page 14: ...Notes 14 ...

Page 15: ...Notes 13 ...

Page 16: ...GE Consumer Industrial General Electric Company Louisville Kentucky 40225 GEAppliances com 2009 General Electric Company SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE ...

Page 17: ...tives il faut porter des gants et des lunettes de sécurité VEUILLEZ LIRE ATTENTIVEMENT ET CONSERVER CES DIRECTIVES IMPORTANT Observez tous les codes et ordonnances en vigueur Note à l installateur Veuillez laisser les présentes directives au consommateur pour l inspecteur local Note au consommateur Veuillez conserver les présentes directives avec votre Manuel d utilisation pour consultation ultéri...

Page 18: ...s et ou bons 2 supports de montage latéraux et 4 vis de montage à tête creuse n 8 pour les comptoirs non fabriqués en bois certains modèles MATÉRIEL NÉCESSAIRE Coude de 90 bague et écrou à compression filetage externe NPT de 9 5 mm 3 8 po à une extrémité et l autre extrémité conçue pour le raccordement à la conduite d alimentation en eau Ruban pour joints filetés Connecteurs vissables homologués U...

Page 19: ...rêtes vives IMPORTANT Lorsque vous branchez le boyau de vidange à un broyeur à déchets assurez vous d enlever le bouchon de vidange LE LAVE VAISSELLE NE POURRA PAS SE VIDER SI VOUS LAISSEZ LE BOUCHON EN PLACE Méthode n 2 Boucle de vidange élevée avec raccord en T ou broyeur à déchets Conseil Pour éviter des frais de réparation inutiles Assurez vous d enlever le bouchon de vidange du broyeur à déch...

Page 20: ... ou un fusible temporisé Le câble électrique doit posséder deux fils plus un fil de mise à la terre et résister à une température nominale de 75 C 176 F Si votre alimentation électrique ne répond pas à ces exigences appelez un électricien agréé avant de poursuivre l installation Mise à la terre Branchement permanent Cet appareil doit être branché à un réseau électrique permanent mis à la terre Sin...

Page 21: ... être exigée par les codes locaux en vigueur Le raccordement de la conduite d eau s effectue du côté gauche du lave vaisselle Installez la conduite d eau chaude en utilisant un tuyau en cuivre de 9 5 mm 3 8 po ou plus Acheminez la conduite d eau de la façon indiquée dans la Figure F et amenez la vers l avant à au moins 48 2 cm 19 po du mur arrière Réglez le chauffe eau à une température variant en...

Page 22: ...erme facilement Vérifiez la porte en l ouvrant et en la fermant Si elle n ouvre pas facilement ou s ouvre trop rapidement vérifiez la disposition du câble du ressort Le câble est retenu en place par des épaulements sur la poulie Assurez vous que le câble est bien installé sur les épaulements de la poulie ÉTAPE 1 PRÉPARATION Prenez les pièces fournies dans l emballage et mettez les de côté en vue d...

Page 23: ...noir blanc et vert du lave vaisselle ont été passés dans le petit trou du support de la boîte de jonction Raccordez le fil blanc ou nervuré du cordon d alimentation au fil blanc du lave vaisselle le fil noir ou lisse au fil noir du lave vaisselle et le fil de mise à la terre au fil vert du lave vaisselle Utilisez des connecteurs vissables homologués UL de la grosseur appropriée Installez le couvercle de...

Page 24: ...centes au fur et à mesure Arrêtez lorsque le lave vaisselle dépasse le devant des armoires adjacentes d environ 15 cm 6 po Assurez vous que le boyau de vidange n est pas plié à l arrière ou en dessous du lave vaisselle Assurez vous que le câble électrique de la résidence le boyau de vidange et la conduite d eau n entrent pas en contact avec des pièces sous le lave vaisselle Figure O Figure P ÉTAPE...

Page 25: ...ce qu ils cassent ÉTAPE 13 INSTLLATION DU LAVE VAISSELLE DANS SON EMPLACEMENT DÉFINITIF Vérifiez l isolant de la cuve s il y a lieu pour vous assurer qu il enveloppe complètement la cuve L isolant ne doit pas retrousser ou entrer en contact avec les ressorts de la porte Si l isolant est déplacé ou entre en contact avec les ressorts replacez le correctement avant de faire glisser l appareil dans so...

Page 26: ...fabriqué à l aide d un matériau qui n accepte pas les vis à bois par exemple en granite utilisez la méthode n 2 IMPORTANT Pour éviter tout dommage au panneau de la porte et au tableau de commande il faut que le lave vaisselle soit installé de manière que le panneau avant et le tableau de commande n entrent pas en contact avec les armoires adjacentes ou le comptoir Vissez les vis complètement et bi...

Page 27: ... mm 7 8 po et un raccord pour relier l extrémité des deux boyaux Fixez le raccord à l aide de colliers Figure W Figure X REMARQUE POUR UNE VIDANGE ADÉQUATE DE L APPAREIL LA LONGUEUR TOTALE DU BOYAU DE VIDANGE NE DOIT PAS DÉPASSER 3 MÈTRES 10 PIEDS 7 2 2 d_ Ta 7 bT 2 P _ Conseil Pour éviter les frais de réparation inutiles pour un problème de vidange Tirez sur le boyau de vidange par l ouverture pr...

Page 28: ...e autre pièce de l appareil Reportez vous à l étape 16 Assurez vous que la conduite d alimentation en eau et le boyau de vidange ne sont pas pliés ou n entrent pas en contact avec d autres pièces Tout contact avec le moteur ou le cadre du lave vaisselle pourrait provoquer l apparition de bruits Ouvrez le robinet d eau chaude de l évier et vérifiez si la température de l eau varie entre 49 C 120 F ...

Page 29: ...rrigez le problème de plomberie au besoin Rétablissez le courant après avoir colmaté la fuite Reportez vous aux étapes 7 et 17 Ouvrez la porte du lave vaisselle et assurez vous que la majeure partie de l eau a été vidangée Si l appareil ne s est pas vidé assurez vous que le bouchon de vidange du broyeur à déchets a été enlevé et ou que la coupure anti refoulement est exempte de débris Vérifiez éga...