– 25 –
Access Cover
To remove the access cover, the oven must be
removed from the installation.
The access cover is attached to the outer cover by 2
Phillips-head screws.
Outer Cover
To remove the outer cover, the oven must be
removed from the installation.
The outer cover is held in place by 22 Phillips-head
screws.
Door Assembly
WARNING:
A microwave leakage test must be
performed any time a door is removed, replaced, or
adjusted for any reason. (See
Diagnostic and Service
Information
.)
Door Removal
Caution:
Do not close the door beyond the door
removal position. Damage to the inner door panel
will occur.
To remove the door, open the door fully and insert a
door removal tool (Part # WB01X10364) in each door
hinge opening. The door can then be slowly closed
a few inches to the door-removal position and lifted
from the oven.
Tool
Tool
Door Hinge Opening
Door-Removal Position