Safety guidelines
4
TruVision NVR 40 User Manual
Safety guidelines
Safe handling
Permanently unplug the unit if you think that it has become damaged and before you
move it.
WARNING:
• A fully assembled TruVision NVR 40 unit can weigh up to 18 kg (40 lb.). Be careful
when lifting it by yourself.
Safety
• The TruVision NVR 40 unit must only be operated from a power supply input
voltage range of 100 to 240 VAC, 50 to 60 Hz.
• The plug on the power supply cord is used as the main disconnect device. Ensure
that the socket outlets are located near the equipment and are easily accessible.
• A safe electrical earth connection must be provided to the power cord. Check the
grounding of the unit before applying power.
• Provide a suitable power source with electrical overload protection to meet the
requirements laid down in the technical specification.
Equipment handling precautions
Caution:
The RJ45 sockets are for Ethernet connection only and must not be
connected to a telecommunications network.
Rack system safety precautions
The following safety requirements must be considered when the unit is mounted in a
rack.
• The unit must be mounted in a 19” rack.
• The rack construction must be capable of supporting the total weight of the
installed unit(s) and the design should incorporate stabilizing features suitable to
prevent the rack from tipping or being pushed over during installation or in
normal use.
• When loading a rack with the units, fill the rack from the bottom up and empty
from the top down.
WARNING:
To avoid danger of the rack toppling over, do not slide more than one unit
out of the rack at a time.