BUILD AND INSTALL THE
ZONELINE BASE PLATFORM
1.
Construct a 23
1
⁄
4
″
min. x 23
1
⁄
4
″
min. square platform.
NOTE:
The platform must have a load-bearing
capacity of 175 lbs. minimum.
1
Installation Instructions
18
WALL PLENUM AND ARCHITECTURAL LOUVER INSTALLATION
• Install the appropriate wall plenum through the exterior wall in accordance with the Installation Instructions
provided with the plenum.
IMPORTANT:
The wall plenum is not designed to carry structural loads.
Proper wall header construction is required. The plenum requires proper
flashing, shim and caulk for a weather resistant installation.
Properly square and
level plenum.
Proper header for
structural support.
Apply proper caulking
and flashing.
Architectural
Louver—RAVAL1
Exterior/Outside Wall
Case
Wall Plenum
RAVWP6 – 6
″
D x 19
3
⁄
4
″
W x 32
″
H
RAVWP8 – 8
″
D x 19
3
⁄
4
″
W x 32
″
H
RAVWP12 – 12
″
D x 19
3
⁄
4
″
W x 32
″
H
RAVWP15 – 15
″
D x 19
3
⁄
4
″
W x 32
″
H
2.
Place the platform in the utility closet with the
following clearance between it and the interior
surface of the walls/door/panel:
•
4
″
min.
from front of the case – Unit to be
installed through
FRONT
of case
•
5
″
min.
from front of the case – Unit to be
installed through
SIDE
of case
•
3
″
min.
from two sides of the case
3.
Align the platform with the opening of
the wall plenum and secure to the floor
using appropriate brackets and bolts.
23
1
⁄
4
″
min.
23
1
⁄
4
″
min.
8
″
min.
for drain
access
Cutout for drain
connection