49-5000545 Rev. 1
5
Alarm
If the bucket is full or missing, an alarm will sound for
about 10 seconds to remind you to empty and replace
the bucket.
Auto Shut Off
The Water Level Control Switch shuts off the
dehumidifier when the bucket is full, or when the bucket
is removed and/or not replaced in the proper position.
NOTE:
The fan and compressor will stop running as
soon as the bucket is removed. The alarm will sound if
the bucket is not replaced in the proper position after 3
minutes.
Auto Defrost
When frost builds up on the evaporator coils, the
compressor will cycle off and the fan will continue to run
until the frost disappears.
Power Outage
In the case of a power outage or interruption, the unit will
automatically restart, in the settings last used, after the
power is restored.
Other Features
OPERA
T
ING INSTRUCTIONS
NOTE
:
This is for 22 and 35 pint models only
. Before plugging in the dehumidifier, remove the casters from the
bucket and install as shown below.
Installing the Casters
1. Remove the 4 casters from the bag taped to the inside
of the water bucket lid.
2. Carefully lay the dehumidifier down on it’s front or back.
3. Following the arrows on the base, slide the 4 casters
into place.
4. Place the unit upright and wait 1 hour before use.
Caster Installation
Dehumidifier is on it’s front
Using the Dehumidifier
How the Dehumidifier Operates
Moist, humid air is drawn over a cold refrigerated
dehumidifying coil. Moisture in the air condenses on this coil
and drains into a bucket (or through a hose and drain).
Dry, clean air is drawn through the condenser where it is
heated and discharged out the top grille into the room.
It is normal for the surrounding air to become slightly
warmer as the dehumidifier operates.
Automatic Defrost
When frost builds up on the evaporator coils, the
compressor will cycle off and the fan will continue to run
until the frost disappears.
When the coil is defrosted, the compressor or fan will
automatically restart and dehumidifying will resume.
When first using the dehumidifier, operate the unit continuously for 24 hours.