background image

5

Installation Preparation

Built-In Speedcook Ovens

Electrical
Requirements

Single Speedcook Installation

Product rating is 120/208 or 120/240 volt, 60
Hz, 30 amps. This product must be connected
to a supply circuit of the proper voltage and
frequency and protected by a time delay fuse
or circuit breaker. The power supply should
be brought to a separate 30 ampere branch
circuit. Wire size must conform to the require-
ments of the National Electric Code or the
prevailing local code.

Install
Junction Box

The conduit is located at the top right on the
back of the oven.
• Locate and install the junction box within

reach of the oven conduit.
– Through the left or right sides of the cabinet

wall and into adjacent cabinet.

– Or, through the cutout floor.
– Or, in the upper cabinet.

Electrical Shock Hazard

• The electrical power to

the oven branch circuit
must be shut off while
line connections are
being made.

• Use copper wiring only.
• Electrical ground is

required on this
appliance. The free end

of the green wire (the ground wire) must be
connected to a suitable ground. This wire
must remain grounded to the oven.

• If cold water pipe is interrupted by plastic,

non-metallic gaskets, union connections or
other insulating materials, DO NOT use for
grounding.

• DO NOT ground to a gas pipe.
• DO NOT  have a fuse in the NEUTRAL or

GROUNDING circuit. A fuse in the
NEUTRAL or GROUNDING circuit could
result in an electrical shock.

• Check with a qualified electrican if you are

in doubt as to whether the appliance is
properly grounded.

Failure to follow these instructions could
result in serious injury or death.

Combined Speedcook and Wall Oven
Installation:

When installed in combination with a GE/
Monogram single wall oven, use separate
electrical junction boxes,
OR,
Install a single junction box connected to 50
amp. supply circuit or properly rated supply
circuit.
• Refer to single oven installation instructions

for electrical requirements of that product.

• These connections must be made by a

qualified electrician. All electrical
connections must meet National Electrical
code or prevailing local codes.

Combined Speedcook and Warming Drawer
installation:

When installing the Speedcook oven over a
GE/Monogram electric warming drawer, a
separate 120V, 60Hz, properly grounded
receptacle must be installed. See instructions
packed with the warming drawer.

21"

Min.

Summary of Contents for Advantium SCB2000

Page 1: ...AdvantiumTM Built In Speedcook Ovens Installation Instructions SCB2000 SCB2001 ZSC2000 ZSC2001...

Page 2: ...444 1845 For Monogram service in Canada call 1 888 880 3030 For Monogram Parts and Accessories call 1 800 626 2002 Use this appliance only for its intended purpose CAUTION This oven should be install...

Page 3: ...For personal safety this oven cannot be installed in a cabinet arrangement such as an island or peninsula Cabinets installed adjacent to wall ovens must have an adhesion spec of at least 194 F tempera...

Page 4: ...l Oven If you are replacing a GE Monogram electric double oven with the combined installation of a Speedcook and single wall oven use the dimensions shown The middle rail separating the two openings m...

Page 5: ...e must remain grounded to the oven If cold water pipe is interrupted by plastic non metallic gaskets union connections or other insulating materials DO NOT use for grounding DO NOT ground to a gas pip...

Page 6: ...ot get pinched between the back of the oven and the cabinet wall Slide oven into the cabinet opening Drill 3 32 pilot holes into the cabinet frame through the 4 mounting holes in the oven front frame...

Page 7: ...ven red lead to branch circuit red lead Connect oven black lead to branch circuit black lead Connect oven green ground lead and white lead to branch circuit neutral white or gray grounding terminal or...

Page 8: ...Pub No 49 40103 SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE DWG NO 164D3370P101 N D 530 2 00 Printed in Korea LG P N 3828W5U0080...

Reviews: