background image

49-5000764   Rev. 0

7

Removing Collected Water (cont)

NOTES:

 

•  

 

Do not remove the bucket while the dehumidifier is 
operating or if it has just stopped operating. This might 
cause some water to drip from the drain pan.

•  

 

The bucket must be in place and securely seated for 
the dehumidifier to operate.

Use a garden hose. 

Water can be automatically emptied 

into a floor drain by attaching a garden water hose (not 
included).

1.  Unscrew the cover to the hose outlet located at the 

rear of the dehumidifier just under the filter. 

2.  Thread a garden hose (not supplied) onto the nozzle 

and ensure it is seated securely.  Cut to length and 
lead it to the floor drain.

3.  Thread a garden hose (not supplied) onto the nozzle 

and ensure it is seated securely. Cut to length and 
lead it to the floor drain.

4.  Replace the bucket in the unit.

NOTE: 

The bucket must be in place and securely seated 

for the dehumidifier to operate. The garden hose must 
run down from the dehumidifier to the floor drain.

Use the internal pump (on some models)

Water can be automatically emptied into a remote 
location by attaching the included pump hose. 

1.  Remove the black rubber drain plug from the garden 

hose attachment exposing the hose bar.

2.  Connect the included hose to the hose barb.  Ensuring 

hose fully covers hose bar to prevent leaks.

3.  Lead the hose discharge to desired drain location.

4.  Make sure pump is activated.  To activate the pump, 

press and hold the Timer button for 3 seconds. The 
Pump On indicator will remain illuminated.

IMPORTANT:

 Make sure the condensate hose is 

properly connected and is not kinked, bent or cracked 
as this may cause water to flow onto the floor. Please 
ensure the bucket is empty before putting the unit into 
pump mode. The bucket must also be fully seated for the 
pump to work properly. Do not operate the machine if the 
room temperature is 41°F or below. 

NOTE:

 Maximum lift height is 16ft.

Using the Dehumidifier

OPERA

TING INSTRUCTIONS

Summary of Contents for ADYR22

Page 1: ...FETY INFORMATION 3 OPERATING INSTRUCTIONS Controls 4 Other Features 5 How the Dehumidifier Operates 5 Choosing a Location 6 Water Level 6 Bucket Operation 6 Removing Collected Water 6 CARE AND CLEANIN...

Page 2: ...s into every GE Appliances product and we think you will too Among other things registration of your appliance ensures that we can deliver important product information and warranty details when you n...

Page 3: ...vision or instruction concerning use of the appliance in a safe way and understand the hazards involved WARNING USE OF EXTENSION CORDS RISK OF FIRE Could cause serious injury or death 2 127 XVH DQ H W...

Page 4: ...n the Clean the Filter indicator light will glow to remind you to clean the filter Remove the filter and clean it Press and hold Filter button for 3 seconds to reset the filter reminder See the Care a...

Page 5: ...he frost disappears When the coil is defrosted the compressor or fan will automatically restart and dehumidifying will resume Power Outage In the case of a power outage or interruption the unit will a...

Page 6: ...e covered with frost at temperatures below 41 F which may reduce performance The suggested range of relative humidity is between 40 and 50 Use the dehumidifier in cooking laundry and dishwashing areas...

Page 7: ...d for the dehumidifier to operate The garden hose must run down from the dehumidifier to the floor drain Use the internal pump on some models Water can be automatically emptied into a remote location...

Page 8: ...out a filter because dirt and lint will clog the unit and reduce performance Grille and Case To clean the case Use water and a mild detergent Do not use bleach or abrasives To clean the rear grille Us...

Page 9: ...away from the dyer The dryer should be vented to the outside Room temperature is too low Moisture removal is best at higher room temperatures Lower room temperatures will reduce the moisture removal...

Page 10: ...liance Statement This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any...

Page 11: ...oviding adequate electrical connecting facilities Failure of the product resulting from modifications to the product or due to unreasonable use including failure to provide reasonable and necessary ma...

Page 12: ...ranty expires In the US GEAppliances com extended warranty or call 800 626 2224 during normal business hours Remote Connectivity For assistance with wireless network connectivity for models with remot...

Page 13: ...s 5 C mo funciona el deshumedificador 5 Selecci n del lugar adecuad 6 C mo desechar el agua acumulada 6 Nivel de agua 6 Funcionamiento del Balde 6 CUIDADO Y LIMPIEZA Rejilla y gabinete 8 Tanque de agu...

Page 14: ...y creemos que usted tambi n Entre otras cosas el registro de su electrodom stico asegura que podamos entregarle informaci n importante del producto y detalles de la garant a cuando los necesite Regis...

Page 15: ...uso de este electrodom stico de una forma segura y entienden los riesgos involucrados ADVERTENCIA USO DE PROLONGADORES RIESGO DE INCENDIO Podr a ocasionar lesiones graves o la muerte 12 XVH SURORQJDGR...

Page 16: ...Reinicio del Filtro HVSXpV GH KRUDV GH RSHUDFLyQ VH HQFHQGHUi OD OX indicadora de Clean the Filter para recordarle que debe limpiar el filtro Quite el filtro y l mpielo Mantenga presionado el bot n d...

Page 17: ...y el ventilador continuar funcionando hasta que la escarcha desaparezca Mientras se descongele la bobina el compresor o ventilador se reiniciar de forma autom tica y el deshumidificador se reiniciar P...

Page 18: ...XHGH reducir su rendimiento O UDQJR VXJHULGR R OD KXPHGDG UHODWLYD HVWi HQWUH 8VH HO GHVKXPHGLILFDGRU HQ iUHDV FRPR OD FRFLQD FXDUWRV de lavado ba os y en reas donde exista humedad excesiva NOTA Coloq...

Page 19: ...estar en su lugar y bien sujeto para TXH HO GHVKXPHGLILFDGRU IXQFLRQH D PDQJXHUD GH MDUGtQ GHEH correr desde el deshumidificador hasta el desag e del piso Use la bomba interna en algunos modelos El ag...

Page 20: ...LQ el filtro debido a que la suciedad y las pelusas lo obstruir n y reducir n su rendimiento Rejilla y gabinete Para limpiar el gabinete 8VH DJXD XQ GHWHUJHQWH GH EDMD FRQFHQWUDFLyQ 1R use blanqueador...

Page 21: ...a del recinto est demasiado baja D GHVKXPHGLILFDFLyQ HV PHMRU D WHPSHUDWXUDV DPELHQWH altas Temperaturas bajas causan bajo rendimiento de deshumedificaci n Modelos est n dise ada para funcionar a WHPS...

Page 22: ...io que intente corregir la interferencia a trav s de una o m s de las siguientes medidas Reoriente o reubique la antena receptora Aumente la separaci n entre el equipo y el receptor Conecte el equipo...

Page 23: ...o posee la capacidad adecuada contacte a su vendedor minorista o instalador Usted es responsable de brindar instalaciones de conexi n el ctrica adecuadas DOOD GHO SURGXFWR FRPR UHVXOWDGR GH PRGLILFDFL...

Page 24: ...OLDQFHV D Q HVWDUiQ DOOt FXDQGR VX JDUDQWtD FDGXTXH Q 88 GEAppliances com extended warranty R OODPH DO GXUDQWH el horario comercial habitual Conectividad Remota Para solicitar asistencia con la conect...

Reviews: