7 Protection Parameter Settings
P50 Agile P153
7-6
P153/EN M/B
Sr. No
Parameter
Defaults setting
Setting / Ranges
11.
DST End Day
Sunday
Sunday / Monday / Tuesday / Wednesday / Thursday /
Friday/ Saturday
Setting to specify the day of the week in which daylight saving time adjustment ends
12.
DST End Month
October
January / February / March / April / May / June / July /
August / September / October / November / December
Setting to specify the month in which daylight saving time adjustment ends
13.
DST End Mins
60 Mins
0 to 1425 mins step 15mins.
Setting to specify the time of day in which daylight saving time adjustment ends. This is set relative to 00:00 hrs on the selected day when
time adjustment is to end
14.
RP Time Zone
Local
UTC / Local
Setting for the rear port 1 interface to specify if time synchronization received will be local or universal time co-ordinated.
15.
SET Hours
10 *
0 to 23 Hrs step 1
Hour setting needed when relay is not connected to SCADA system
16.
SET Minutes
35 *
0 to 59 Mins step 1
Minutes setting needed when relay is not connected to SCADA system
17.
SET Seconds
54 *
0 to 59 Sec. step 1
Seconds setting needed when relay is not connected to SCADA system
18.
SET Date
28 *
1 to 31 Days step 1
Date setting needed when relay is not connected to SCADA system
19.
SET Month
10 *
1 to 12 Months step 1
Month setting needed when relay is not connected to SCADA system
20.
SET Year
14 *
0 to 99 Years step 1
Year setting needed when relay is not connected to SCADA system
Note: * The relay displays the current Date/Time set in the relay.
2.4
CONFIGURATION Settings
Sr. No
Parameter
Defaults setting
Setting / Ranges
1.
Password
0000
0000 to zzzz
This setting specifies to enter the set password
2.
Restore Defaults
No Operation
No Operation / All Settings / Setting Group 1 / Setting
Group 2
This setting restores the chosen setting groups to factory default values.
To restore the default values to any Group, set the ‘restore defaults’ cell to the relevant Group number. Alternatively it is possible to set
the ‘restore defaults’ cell to ‘all settings’ to restore the default values to all of the IED’s settings, not just the Group settings.
The default settings will be placed in Flash and will only be used by the IED after they have been confirmed by the user.
Note:
Restoring defaults to all settings includes the rear communication port settings, which
may result in communication via the rear port being disrupted if the new (default)
settings do not match those of the master station
3.
Active Settings
Group 1
Group 1 / Group 2
This setting selects the active settings group.
4.
Copy From
Group 1
Group 1 / Group 2
This setting allows settings to be copied from a selected setting group.
Summary of Contents for Agile P50 Series
Page 3: ...P50 Agile P153 1 Introduction P153 EN M B 1 1 INTRODUCTION CHAPTER 1...
Page 4: ...1 Introduction P50 Agile P153 1 2 P153 EN M B...
Page 10: ...1 Introduction P50 Agile P153 1 8 P153 EN M B...
Page 11: ...P50 Agile P153 2 Safety Information P153 EN M A 2 1 SAFETY INFORMATION CHAPTER 2...
Page 22: ...Chapter 2 Safety Information P50 Agile P153 2 12 P153 EN M A...
Page 23: ...P50 Agile P153 3 Hardware Design P153 EN M B 3 1 HARDWARE DESIGN CHAPTER 3...
Page 24: ...3 Hardware Design P50 Agile P153 3 2 P153 EN M B...
Page 32: ...3 Hardware Design P50 Agile P153 3 10 P153 EN M B...
Page 33: ...P50 Agile P153 4 Front Panel P153 EN M B 4 1 FRONT PANEL CHAPTER 4...
Page 34: ...4 Front Panel P50 Agile P153 4 2 P153 EN M B...
Page 39: ...P50 Agile P153 5 Configuration P153 EN M B 5 1 CONFIGURATION CHAPTER 5...
Page 40: ...P50 Agile P153 5 Configuration P153 EN M B 5 2...
Page 150: ...P50 Agile P153 5 Configuration P153 EN M B 5 112...
Page 151: ...P50 Agile P153 6 Protection Functions P153 EN M B 6 1 PROTECTION FUNCTIONS CHAPTER 6...
Page 152: ...6 Protection Functions P50 Agile P153 6 2 P153 EN M B...
Page 168: ...7 Protection Parameter Settings P50 Agile P153 7 2 P153 EN M B...
Page 189: ...P50 Agile P153 8 Monitoring Control P153 EN M B 8 1 MONITORING CONTROL CHAPTER 8...
Page 190: ...8 Monitoring Control P50 Agile P153 8 2 P153 EN M B...
Page 207: ...P50 Agile P153 9 SCADA Communications P153 EN M B 9 1 SCADA COMMUNICATIONS CHAPTER 9...
Page 208: ...12 SCADA Communications P50 Agile P153 9 2 P153 EN M B...
Page 220: ...12 SCADA Communications P50 Agile P153 9 14 P153 EN M B...
Page 221: ...P50 Agile P153 10 Installation P153 EN M B 10 1 INSTALLATION CHAPTER 10...
Page 222: ...10 Installation P50 Agile P153 10 2 P153 EN M B...
Page 234: ...13 Commissioning Instructions P50 Agile P153 13 2 P153 EN M B...
Page 242: ...12 Maintenance and Troubleshooting P50 Agile P153 12 2 P153 EN M B...
Page 250: ...12 Maintenance and Troubleshooting P50 Agile P153 12 10 P153 EN M B...
Page 252: ...13 Technical Specifications P50 Agile P153 13 2 P153 EN M B...
Page 263: ...P50 Agile P153 14 Wiring Diagrams P153 EN M B 14 1 WIRING DIAGRAMS CHAPTER 14...
Page 264: ...14 Wiring Diagrams P50 Agile P153 14 2 P153 EN M B...
Page 267: ......