background image

3828A21031B

49-7523     11-05 JR

AGN05
AGQ05

AGS05

AGV05

Owner’s Manual and

Installation Instructions

Write the model and serial numbers here:

Model # __________________________

Serial # __________________________

Find these numbers on a label on the
side of the air conditioner.

A

ir Condit

io

ners

ge.com

Room

Safety Instructions

 . . . . . . . . .2, 3

Operating Instructions

Control knob models  . . . . . . .6, 7
Touch pad models  . . . . . . . . . .4, 5

Care and Cleaning

Air Filter  . . . . . . . . . . . . . . . . . . .8
Front Grille and Case  . . . . . . . . .8
Normal Operating Sounds  . . . . .8
Outdoor Coils  . . . . . . . . . . . . . . .8

Installation Instructions

 . . .9–13

Troubleshooting Tips

 . . . . . . .14

Consumer Support

Consumer Support  . . . . . . . . . .18
Product Registration  . . . . . .15, 16
Warranty  . . . . . . . . . . . . . . . . . .17

Summary of Contents for AGN05

Page 1: ...d these numbers on a label on the side of the air conditioner Air Conditioners ge com Room Safety Instructions 2 3 Operating Instructions Control knob models 6 7 Touch pad models 4 5 Care and Cleaning Air Filter 8 Front Grille and Case 8 Normal Operating Sounds 8 Outdoor Coils 8 Installation Instructions 9 13 Troubleshooting Tips 14 Consumer Support Consumer Support 18 Product Registration 15 16 W...

Page 2: ...o product disposal If you are getting rid of an old product with refrigerants check with the company handling disposal about what to do SAFETY PRECAUTIONS Do not under any circumstances cut or remove the third ground prong from the power cord For personal safety this appliance must be properly grounded The power cord of this appliance is equipped with a 3 prong grounding plug which mates with a st...

Page 3: ...utlet by use of a UL listed adapter available at most local hardware stores The larger slot in the adapter must be aligned with the larger slot in the wall outlet to provide proper polarity in the connection of the power cord When disconnecting the power cord from the adapter always hold the adapter in place with one hand while pulling the power cord plug with the other hand If this is not done th...

Page 4: ...mperature or time remaining on timer MODE Use to set the air conditioner to COOL or FAN mode Increase Decrease Pads Use to set temperature when in COOL mode FAN Pad Use to set the fan speed to LOW F1 MED F2 or HIGH F3 TIMER Pad ON When the air conditioner is off it can be set to automatically come on in 1 to 12 hours at its previous setting Each touch will set the timer in hours OFF When the air c...

Page 5: ...ressor to start and cooling to begin Cooling Descriptions For Normal Cooling Select the COOL mode and HIGH F3 or MED F2 fan with a middle set temperature For Maximum Cooling Select the COOL mode and HIGH F3 fan with a lower set temperature For Quieter Nighttime Cooling Select the COOL mode and LOW F1 fan with a middle set temperature NOTE If you switch from a COOL setting to OFF or to a fan settin...

Page 6: ...o become cooler Turn the knob toward the smaller blue area for the indoor air to become warmer The Mode Temp control is used to maintain the room temperature When set in the COOL ON mode the compressor will cycle on and off to keep the room at the same level of comfort Cooling Descriptions For Normal Cooling Select the COOL ON mode with the Mode Temp knob set at the midpoint For Maximum Cooling Se...

Page 7: ...ctions Safety Instructions Installation Instructions 7 Air Direction Fingertip pressure on the louvers lets you control the air direction left right straight ahead or any combination of these directions ge com Additional controls and important information ...

Page 8: ...ilter because dirt and lint will clog it and reduce performance To remove Grasp the tab and gently pull the filter up and out Outdoor Coils The coils on the outdoor side of the air conditioner should be checked regularly If they are clogged with dirt or soot they may be professionally cleaned Air Filter Normal Operating Sounds You may hear a pinging noise caused by water being picked up and thrown...

Page 9: ...e is only a 2 prong outlet it is your responsibility to have it replaced with a properly grounded 3 prong wall outlet Some models require 230 208 volt a c protected with a time delay fuse or circuit breaker These models should be installed on their own single branch circuit for best performance and to prevent overloading house or apartment wiring circuits which could cause a possible fire hazard f...

Page 10: ...am top window gasket Window sash seal Side accordion panels 10 Installation Instructions PARTS INCLUDED Appearance may vary Support brackets 3 Type A 2 Type B 14 Air conditioner Type C 2 Top mounting rail ...

Page 11: ... wood to the stool WOOD PIECES WIDTH 2 LENGTH Long enough to fit inside the window frame THICKNESS To determine the thickness place a piece of wood on the stool to make it 1 2 higher than the top of the storm window frame Attach securely with nails or screws provided by the installer 1 2 higher than frame Storm window frame Wood Stool 2 11 PREPARE THE WINDOW Cut the window sash seal to the window ...

Page 12: ... fill the window opening and use 2 Type A screws to secure the top corners and 2 Type C screws to secure the bottom corners 5 A B C Top mounting rail Type A screw Type A screw Type C screw Type C screw Window 1 3 bubble Bottom mounting rail Support brackets INSTALL THE TOP MOUNTING RAIL AND THE SIDE ACCORDION PANELS Install the top mounting rail with 3 Type B screws from the outside of the case Sl...

Page 13: ...NDOW GASKET Attach a support bracket with a Type B screw Cut the foam top window gasket to the window width Stuff the foam between the glass and the window to prevent air and insects from getting into the room 6 A B C Installation Instructions 13 ...

Page 14: ...Check for open furnace floor registers and cold air returns Set the air conditioner s vent to the closed position Cooling coils have iced up See Air conditioner freezing up below Air conditioner Ice blocks the air flow On models with a control knob turn it to FAN ONLY or freezing up and stops the air conditioner COOL ON set at the small blue area from cooling the room On models with touch pads set...

Page 15: ...otection or you may request your money back on the remaining value of your contract No questions asked It s that simple Protect your refrigerator dishwasher washer and dryer range TV VCR and much more any brand Plus there s no extra charge for emergency service and low monthly financing is available Even icemaker coverage and food spoilage protection is offered You can rest easy knowing that all y...

Page 16: ...ut here Complete and mail your Consumer Product Ownership Registration today Have the peace of mind of knowing we can contact you in the unlikely event of a safety modification After mailing the registration below store this document in a safe place It contains information you will need should you require service Our service number is 800 GE CARES 800 432 2737 Read your Owner s Manual carefully It...

Page 17: ...duct caused by improper power supply voltage accident fire floods or acts of God Incidental or consequential damage caused by possible defects with this air conditioner Damage caused after delivery Product not accessible to provide required service What Is Not Covered This warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA If ...

Page 18: ...rranty and learn about special discounts that are available while your warranty is still in effect You can purchase it on line anytime or call 800 626 2224 during normal business hours GE Consumer Home Services will still be there after your warranty expires Parts and Accessories ge com Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes...

Page 19: ...ionar problemas 14 Sonidos normales de operación 15 Servicio al consumidor Garantía 17 Servicio al consumidor 18 3828A21031B 49 7523 11 05 JR Escriba los números de modelo y serie aquí de Modelo __________________ de Serie ____________________ Puede encontrar estos números en una etiqueta en el costado del acondicionador de aire AGN05 AGQ05 AGS05 AGV05 Manual del propietario e Instrucciones de Ins...

Page 20: ...anea deshacerse de algún producto que contenga refrigerantes póngase en contacto con la compañía que se encarga de recoger su basura para que le indiquen qué hacer PRECAUCIONES DE SEGURIDAD Bajo ninguna circunstancia corte o remueva la tercera púa tierra del cable eléctrico En pos de la seguridad personal este electrodoméstico debe siempre conectarse a tierra El cable eléctrico de este electrodomé...

Page 21: ...ranura mayor en el adaptador debe estar alineada con la púa mayor en la pared para proporcionar una polaridad apropiada en la conexión del cable eléctrico Cuando se disponga a desconectar el cable eléctrico del adaptador siempre sostenga el adaptador en su lugar con una mano mientras tira del cable eléctrico con la otra mano Si no hace esto la terminal de tierra del adaptador podría romperse despu...

Page 22: ...a velocidad del ventilador a LOW F1 BAJO MED F2 o HIGH F3 ALTO TIMER SINCRONIZADOR ON ENCENDIDO Cuando el acondicionador de aire está apagado puede ajustarse para que se encienda automáticamente dentro de 1 a 12 horas en el nivel previo Cada toque ajustará el tiempo en horas OFF APAGADO Cuando el acondicionador de aire está encendido puede ajustarse para que se apague automáticamente dentro de 1 a...

Page 23: ...nfriamiento Para enfriamiento normal Seleccione el modo de ventilador COOL FRÍO y HIGH F3 ALTO o MED F2 MEDIO con una temperatura de ajuste media Para enfriamiento máximo Seleccione el modo de ventilador COOL y HIGH F3 ALTO con una temperatura de ajuste menor Para enfriamiento silencioso y enfriamiento nocturno Seleccione el modo de ventilador COOL y LOW F1 BAJO con una temperatura de ajuste media...

Page 24: ... Gire el botón hacia COOLER MÁS FRÍO hacia el área azul mayor para que el aire de interior se enfríe más Gire el botón hacia el área azul más pequeña para que el aire de interior se caliente más El control de Mode Temp es usado para mantener a temperatura ambiente Cuando esté colocado en el modo COOL ON ENFRIADO ENCENDIDO el compresor hará ciclo entre apagado y encendido para mantener el salón al ...

Page 25: ...re las persianitas para cambiar la dirección del aire de derecha a izquierda y en dirección recta o en combinaciones de estas direcciones ge com Controles adicionales e información importante Servicio al consumidor Solucionar problemas Operación Seguridad Instalación ...

Page 26: ...os cada 30 días o más a menudo si fuese necesario Limpie el filtro con agua tibia y jabón Enjuáguelo y permita que se seque antes de colocarlo otra vez en su lugar PRECAUCIÓN NO OPERE el acondicionador de aire sin el filtro debido a que la suciedad y las pelusas lo obstruirán y reducirán su rendimiento Para retirarlo Agarre la orejilla en el filtro y tire hacia afuera y hacia arriba Bobinas para e...

Page 27: ...e la pared que usted planea usar solamente tiene 2 tomas es su responsabilidad hacer que un técnico lo reemplace por uno de tres tomas con conexión a tierra REQUISITOS ELECTRICOS Algunos modelos requieren 230 208 voltios de corriente alterna protegidos por un fusible de dilatación de tiempo o un cortacircuitos Estos modelos deberían instalarse en un ramal exclusivo del circuito para un rendimiento...

Page 28: ...de acordeón PARTES INCLUIDAS El aspecto puede variar Soportes de apoyo 3 Tipo A 2 Tipo B 14 Acondicionador de aire 10 Instrucciones de instalación Tipo C 2 Riel de montaje superior HERRAMIENTAS QUE USTED NECESITARÁ Destornillador Phillips Regla o cinta métrica Lápiz Nivel Tijeras o cuchilla ...

Page 29: ... la repisa PIEZAS DE MADERA ANCHO 2 LONGITUD Suficiente longitud para ajustarse al interior del marco de la ventana ESPESOR Para determinar el espesor coloque un pedazo de madera en la repisa para hacerlo 1 2 más alto que la parte superior del marco de la ventana de tormentas Una firmemente con puntillas o tornillos provistos por el instalador 1 2 más alto que el marco Marco de ventana de tormenta...

Page 30: ...dor de aire en la ventana con el riel de montaje inferior entre la repisa de la ventana y los soportes Cierre la ventana Asegúrese de que el marco de la ventana está detrás del riel de montaje superior del acondicionador de aire Debe estar nivelado o ligeramente inclinado hacia el exterior Use un nivel una inclinación de 1 3 de burbuja será la correcta hacia el exterior Extienda los paneles de aco...

Page 31: ...AQUE SUPERIOR DE ESPUMA DE LA VENTANA Pegue un soporte de apoyo con un tornillo tipo B Corte el empaque superior de espuma de la ventana al ancho de la ventana Rellene la espuma entre el vidrio y la ventana para evitar que el aire y los insectos entren al cuarto 6 A B C ...

Page 32: ... los registros de la calefacción no están abiertos y se encuentran retornando el aire frío Coloque la ventanilla del acondicionador de aire en la posición cerrada Las bobinas de enfriamiento Ver Acondicionador de aire congelándose más adelante se congelaron El acondicionador de aire El hielo bloquea el flujo En modelos con un botón de control gírelo hacia se está congelando de aire hacia el acondi...

Page 33: ...mover la humedad y mejora la eficiencia Quizás escuche que el termostato hace clic cuando el compresor hace ciclo entre encendido y apagado El agua se acumula en la bandeja durante días lluviosos o con mucha humedad El agua podría derramarse y gotear desde el lado externo de la unidad El ventilador podría funcionar aun si el compresor no lo hace Servicio al consumidor Solucionar problemas Operació...

Page 34: ...16 Notas Servicio al consumidor Solucionar problemas Operación Seguridad Instalación ...

Page 35: ...aciones o actos de la naturaleza de fuerza mayor Daños incidentales o consecuenciales causados por defectos posibles con este acondicionador de aire Daños después de la entrega Producto no accesible para facilitar el servicio requerido Lo que no está cubierto Esta garantía se extiende al comprador original y cualquier comprador posterior de productos comprados para uso residencial dentro de Estado...

Page 36: ...ales disponibles mientras su garantía está aún activa Puede comprarla en línea en cualquier momento o llamar al 800 626 2224 durante horas normales de oficina GE Consumer Home Services estará aún ahí cuando su garantía termine Piezas y accesorios ge com Aquellos individuos con la calificación necesaria para reparar sus propios electrodomésticos pueden pedir que se les manden las piezas o accesorio...

Reviews: