Removing Collected Water
There are 3 ways to remove collected water:
Use the bucket.
When the bucket is removed,
the unit will shut off. Empty and replace the
bucket.
Use a hose.
Water can be automatically
emptied into a floor drain by attaching a
water hose to the bucket. Using a drill, make a
hole at the end of the nozzle located on the
lower left side of the bucket. Attach a water
hose to the bucket nozzle.
Use a floor drain.
The unit can also be placed
over a floor drain. Using a drill, make a hole
at the end of the nozzle located on the lower
left side of the bucket.
NOTE:
The nozzle cannot be fixed after puncture. Use
an ordinary garden hose cap to reclose if necessary.
Consumer Support
Troubleshooting T
ips
Operating Instructions
Safety Instructions
Care and Cleaning
5
Using the dehumidifier.
GEAppliances.com
When first using the dehumidifier, operate the unit continuously 3 to 4 days.
Choosing a Location
■
The dehumidifier must be operated in an enclosed
area to be most effective.
■
Close all doors, windows and other outside openings
to the room.
Place the dehumidifier in a location that does
not restrict air flow into the rear coil or out the
front grille.
A dehumidifier operating in a basement will have
little or no effect in drying an adjacent enclosed
storage area, such as a closet, unless there is
adequate circulation of air in and out of the area.
How the Dehumidifier Operates
Moist, humid air is drawn over a cold refrigerated
dehumidifying coil. Moisture in the air condenses
on this coil and drains into a bucket (or through
the bucket into a hose and drain).
Dry, clean air is drawn over the condenser where it
is actually heated several degrees and discharged
out the front grille into the room.
It is normal for the surrounding air to become slightly
warmer as the dehumidifier operates.
This warming effect further reduces the relative
humidity of the surrounding air.
Evaporator
Condenser
Humid air in
Drain pan
Drain connector
Bucket
Nozzle
Nozzle
Hose
Compressor
Fan
Humidistat
Dry air out