7.1.2.1.2 Protection Function
Anti Freezing Protections
When the system tested anti-freezing protection, the compressor will stop, the outdoor fan will delay 15 seconds and stop running .
Function Manual of Remote Controller
7
7
7
7
7
7.
.
.
.
.1
1
1
1
1
Remote Controller Function Manual
7.1.2.2 Dry Mode
7.1.2.2.1 The condition and processes of dehumidifying
When Tamb Tset+2
, Dry and Cooling modes will act,compressor, outdoor fan will run at setting fan speed.
When Tset-2
Tamb
Tset+2
, Dry mode will act, at this time indoor fan runs at low fan speed,compressor will run 6mins and
will stop running, outdoor fan will delay 15s and stop. 3.45 mins later, compressor, outdoor fan and indoor fan motor restart
Over Current protection
When the system is tested, the compressor will stop, the outdoor fan will delay 15 seconds and stop running. The indoor fan will
run at the set speed. When antifreezing protection is eliminated and compressor has stopped for 3min, the system will resume
operation.
Compressor
Outdoor Fan
Indoor Fan
Min.
During anti-freezing
Stop
Running
Setting fan speed
7.1.1 Temperature Parameter
The room set temperature (Tset)
The room ambient temperature (Tamb)
7.1.2 System Fundamental functions
7.1.2.1 Cooling mode
If T
amb
T
set
+1
, COOL mode will act, the compressor and the outdoor fan will run, the indoor fan will run at the setting speed.
If T
amb
T
set
-
-
-
-
-
1
, Compressor and outdoor fan will have a delay of 15 seconds and stop, indoor fan will run at the setting speed
If T
set
-1
T
amb
T
set
+1
, the unit will keep running in the old mode.
In this mode, the 4-way valve will not power on, the setting temp. range:16
~30
.
Start Cooling
Original Running State
Stop Cooling
set
set
amb
Min.
Min.
Min.
Setting Fan Speed
Stop
Running
Compressor
Outdoor Fan
Indoor Fan
˚
ć
ı
İ
˘
˘
ć
ć
ć
ć
ć
ć
ć İ
ć
İ