22
operation procedures/pictures
8.2.7
Disassemble axial flow fan
Screw off the nuts of fan blade by spanner, and
could take off the fan blade.
As shown in Fig.8-18
Fig.8-18
8.2.8
Disassemble the outdoor motor
Screw off 4pcs tapping screws fixing the motor,
and pull out the motor lead wire connection
insert, and disassemble the motor. Screw off
2pcs tapping screws from the motor support,
and lift it upward, disassemble the motor
support.
As shown in Fig.8-19
(Only for cooling and heating unit)
Screw off the fixing nuts for fixing the solenoid of
4-way valve and remove the solenoid. Wrap the 4-
way valve with wet cotton gauze. It is recommended
to solder as quickly as possible and the cotton
gauze should always be wet. Make sure not to
burn the leads of compressor by the fame.
As shown in Fig.8-20
8.2.9
Disassemble 4-way valve
Fig.8-19
Fig.8-20
Motor
Motor Fixing Screw
Motor Support
Fixing Screw
Motor Wire
Solder Point
4-way valve
AxialFlow Fan
Firm Nut