9
Sa
fet
y In
str
uc
tio
ns
O
pe
ra
tin
g I
ns
tru
cti
on
s
Ca
re
a
nd
C
lea
nin
g
In
sta
lla
tio
n In
str
uc
tio
ns
Tro
ub
les
ho
oti
ng
Tip
s
Co
ns
um
er
Su
pp
or
t
GEAppliances.com
When connected, the unit will be controlled
by a remote thermostat.
NOTE:
The number 3 dip switch must be in
the enabled
(UP)
position to activate the remote
thermostat. (See the installation instructions
supplied with the remote thermostat.)
IMPORTANT:
The thermostat connections provide 24 V AC only.
If using a digital/electronic wall thermostat,
ensure it is compatible with 24 VAC signal. See
the Installation Instructions for the wall thermostat.
NOTICE:
Damage to a wall thermostat or to the electronics
can result from improper connections. Special
care must be used in connecting the wires. No line
voltage connections should be made to any circuit.
Isolate all wires in building from line voltage.
Terminal Connections Remote Thermostat - Class 2 (on some models)
The controls are located under a plastic cover
behind the front grille.
1
Remove the front grille. See the Front Grille
section of Care and Cleaning.
2
Remove the screws securing the plastic cover
over the wiring connections. Set aside screws
and plastic cover.
3
To make wiring connections, insert the wires
into the bottom of the terminals and tighten
screws securely.
4
After all desired connections have been made,
replace the plastic cover and front grille.
The owner is responsible for making all
connections and setting the appropriate dip
switches.
Terminal
connections
location
under front
grille