Model T9 Ultrasonic Flow Transducer Installation Guide
31
Chapter 5. T9 Specifications
Chapter 5. T9 Specifications
5.1 Specifications
Table 2: T9 Transducer Specifications
Transducer
T9 Specification
Designation
Hazardous area applications; flare gas, hydrocarbon gases, saturated steam.
Installation Type
Wetted
Material
Standard:
Titanium
Optional:
316SS, Monel
or Hastelloy
Field Mounting
Flowcell, hot or cold tap
Process Connection
1.5 in. (40 mm) flanged
Holder Type
Simple, barrel or flanged holder
Holder Ratings
150#, 300#, 600#
Operating Frequency
100 kHz
Pressure Range
0 to 2700 psig
Electrical Rating
200 V peak-to-peak, 5 mA
Ambient Temperature Range
Europe:
-40 to +158°F (-40 to +70°C)
North America:
-4 to +140°F (-20 to +60°C)
Process Temperature Range
Normal Temperature:
-58 to +302°F (-50 to +150°C)
High Temperature:
-58 to +500°F (-50 to +260°C)