20
49-80520-8
Troubleshooting tips ...
Before you call for service
TROUBLESHOOTING TIPS
Save time and money! Review the charts on the following pages first and you may not need to call for service.
Problem
Possible Cause
What To Do
Fan does not operate when
the switch is on
A fuse may be blown or a
circuit breaker tripped.
Replace fuse or reset circuit breaker.
The blower connector is loose
or not plugged into its mating
connector.
Disconnect power to the unit. Remove the filters and
look up at the blower. If the blower connector plug is
loose or you see the connector dangling, the installer
failed to plug it in securely. Although it is a blind
connection, it is easy to plug in. See the Installation
Instructions in this manual for the plug location and how
to plug the connector in.
Fan fails to circulate air
or moves air slower than
normal
Excessively soiled filters.
Remove the filters, clean if necessary and replace them.
If cleaning and replacing the filters does not correct the
problem, call for service.
Sufficient makeup (replacement) air is required for
exhausting appliances to operate to rating. Check with
local building codes, which may require or strongly
advise the use of makeup air. Visit
GEAppliances.com
for available makeup air solutions.