12
Arize Element
®
L1000 Gen2
Installation Guide
3.2.2 Using Custom
AC Inputs
3.2.1 Connect the Driver Input
CLICK!
AC line
To driver input
Connect the yellow/green wire to
the incoming ground conductor.
Connect the brown wire to Line 1
and blue wires to Neutral or Line 2
of the incoming AC line.
>P
A<
Pin
Line-to-Line
Voltage
Line-to-Neutral
Voltage
1
L2
L1
L1
L1
L2
L3
2
L3
L2
L3
N
N
N
PE
PE
PE
PE
PE
PE
PE
L=Line / N=Neutral / PE=Protective Earth
3.2.3 Connect Bead to
AC Input Leader Cable
Connect 2 beads provided, the
first bead should be no more than
20 mm from input connector.
20mm
If you choose to use your own
custom AC input connection, use a
Wieland RST20i3 green connector
(96.031.4055.7 OR 96.031.4155.7 OR
96.031.0055.7 OR 96.031.1055.7)
and plug into the male AC connector
of the driver.
3.2.4 Connecting Driver
to AC Line
NOTE:
To disassemble connectors,
insert and twist a small blade
screwdriver and then separate
connectors.
Align keying features on driver
with connector on the selected
leader cable.
Push connectors together until
a click is heard.
Secure AC input leader cable,
away from driver and light
module.
1
2
3
Connector pin-out
1
2
PE