SEQUENCE of OPERATION
PAGE
24
ENGLISH
59°F // ice5
46°F // ice2
43°F
Decreasing slowly
Decreasing rapidly ice_temp_1
Stop
Keeping the frequency
Increasing slowly
32°F
Tpg1=37°F
Tpg2=41°F
Tpg3=43°F
Tpg4=
48°F
3. Compressor Overcurrent Protection
4. Indoor Coil Freeze Protection
If the current draw of the compressor at start-up is greater
than the values in the chart below for approximately 3 seconds,
the compressor will stop and a code will be indicated at the
outdoor unit. After 3 minutes the compressor will restart.
If the overcurrent condition occurs 3 times in 20 minutes,
the system will lock out.It will be necessary to remove power
to the system to reset the lock outcondition.
Tpg_indoor: indoor unit pipe sensor temperature
When Tpg_indoor < Tpg1, the frequency of the compressor
decreases at the rate of 1HZ / 1 second.
When Tpg_indoor < Tpg2, the frequency of the compressor
decreases at the rate of 10HZ / 10 seconds.
When Tpg3 < Tpg_indoor <Tpg4, the frequency of the compressor
increases at the rate of 1HZ / 10 seconds.
outdoor unit will stop and indicate an underload malfunction
code at the outdoor unit. The compressor stops for a minimum
of 3 minutes. When Tpg_indoor >Tpg4, the compressor
will restart.
The coil sensor protects the coil from becoming too cold during
low cooling load days or periods of high humidity.
Current overload protection
No charge
12A
09K
12K
18K
24K
13A
14A
14A
15A
17A
15A
14.5A
15.5A
20A
19A
13.5A
18A
13A
13A
17A
Decrease 1Hz/10s
Decrease 1Hz/s
Over Current Point
Summary of Contents for ASYW09CRAWA
Page 2: ...This page intentionally left blank...
Page 6: ...INTRODUCTION PAGE 6...
Page 26: ...INSTALLATION PAGE 42 ENGLISH This page intentionally left blank...
Page 58: ...REFERENCE INFORMATION PAGE 58 ENGLISH Outdoor Board Schematic 9 12K...
Page 59: ...REFERENCE INFORMATION PAGE 59 Outdoor Board Schematic Outdoor Board Schematic ENGLISH...
Page 63: ...REFERENCE INFORMATION PAGE 63 ENGLISH Indoor Board Schematic 09 12K...