Save time and money! Review the chart below first and you may not need to call for service.

Problem

Possible Causes

What To Do

Dehumidifier 

The dehumidifier 

Make sure the dehumidifier’s plug is pushed completely 

does not start

is unplugged.

into the outlet.

The fuse is blown/circuit

Check the house fuse/circuit breaker box and replace

breaker is tripped.

the fuse or reset the breaker.

Dehumidifier has reached its 

The dehumidifier automatically turns off when either

preset level or bucket is full. 

condition occurs. Change to a lower setting or empty 
the bucket and replace properly.

Bucket is not in the 

The bucket must be in place and securely seated for the 

proper position.

dehumidifier to operate. 

Power failure.

There is a protective time delay (up to 3 minutes) to 
prevent tripping of the compressor overload. For this 
reason, the unit may not start normal dehumidifying 
for 3 minutes after it is turned back on.

Dehumidifier does not

Did not allow enough time 

When first installed, allow at least 24 hours to maintain 

dry the air as it should

to remove the moisture. 

the desired dryness.

Airflow is restricted. 

Make sure there are no curtains, blinds or furniture 
blocking the front or back of the dehumidifier. See the 

Choosing a Location

section.

Dirty filter.

See the 

Care and Cleaning

section.

The Humidity Control may 

For drier air, press the 

pad and set to a lower percent 

not be set low enough. 

value (%) or at 

CO

(continuous) for maximum 

dehumidification.

Doors and windows may not 

Check that all doors, windows and other openings 

be closed tightly. 

are securely closed.

Clothes dryer may be 

Install the dehumidifier away from the dryer. 

blowing moisture-laden 

The dryer should be vented to the outside. 

air into the room. 

Room temperature 

Moisture removal is best at higher room temperatures. 

is too low. 

Lower room temperatures will reduce the moisture 
removal rate. Models are designed to be operated at 
temperatures above 41°F (5°C).

Dehumidifier runs

Area to be dehumidified 

The capacity of your dehumidifier may not be adequate. 

too much

is too large. 

Doors and windows are open. 

Close all doors and windows to the outside. 

Frost appears on 

Dehumidifier has been turned 

This is normal. Frost will usually disappear 

the coils

on recently, or room temperature 

within 60 minutes. See the

Automatic Defrost

section.

is below 41°F (5°C). 

Controls cannot be set

The compressor will turn off 

This is normal. Wait approximately 3 minutes and set the 

and the fan will automatically 

fan as desired.

continue to run for 
approximately 3 minutes at a 
fixed setting.

Fan noise 

Air is moving through

This is normal. 

the dehumidifier. 

Water on floor

Hose connection may be loose.

Check the hose connection. See the 

Removing Collected 

Water

section. 

Intended to use the bucket to 

Disconnect the hose if using the bucket to collect water. 

collect water, but a hose

See the 

Removing Collected Water 

section.

is attached.

Summary of Contents for AZ61H12DAB

Page 1: ...ERGY STAR labeled product As an ENERGY STAR partner GE has determined that this product meets the ENERGY STAR guidelines for energy efficiency ge com Dehumidifiers 49 7613 11 08 JR AHW30 AHW50 AHW65 O...

Page 2: ...ing rid of an old product with refrigerants check with the company handling disposal about what to do Do not use outdoors This dehumidifier is intended for indoor residential applications only This de...

Page 3: ...ential safety hazards under certain conditions we strongly recommend against the use of an extension cord However if you must use an extension cord it is absolutely necessary that it be a UL listed 14...

Page 4: ...control to High for maximum moisture removal When the humidity has been reduced and quiet operation is preferred set the fan control to Medium or Low Delay Off While the dehumidifier is in operation...

Page 5: ...reas that have excessive moisture NOTE Place the dehumidifier away from the clothes dryer Use the dehumidifier to prevent moisture damage anywhere books or valuables are stored Use the dehumidifier in...

Page 6: ...can be automatically emptied into a floor drain by attaching a garden water hose not included 1 Remove the bucket from the front of the unit 2 Open the drain cover on the side of the unit 3 Thread a...

Page 7: ...replace Slide the bucket into the dehumidifier NOTE The bucket must be in place and securely seated for the dehumidifier to operate Air Filter The air filter behind the front grille should be checked...

Page 8: ...Dirty filter See the Care and Cleaning section The Humidity Control may For drier air press the pad and set to a lower percent not be set low enough value or at CO continuous for maximum dehumidifica...

Page 9: ...erly pack your unit We recommend using the original carton and packing materials Return the product to the retail location where it was purchased Include in the package a copy of the sales receipt or...

Page 10: ...nce la client le Assistance la client le 19 Garantie 18 Inscrivez ici les num ros de mod le et de s rie Num ro de mod le ______________ Num ro de S rie ________________ Vous les trouverez sur une tiqu...

Page 11: ...ancien appareil contenant des fluides frigorig nes v rifiez la proc dure suivre aupr s de la compagnie responsable de l limination N utilisez pas le d shumidificateur l ext rieur Ce d shumidificateur...

Page 12: ...igatoirement tre homologu e UL de calibre 14 trois brins pour une mise la terre et doit tre quip e d une fiche et d une prise femelle avec terre Les caract ristiques lectriques de la rallonge doivent...

Page 13: ...r choisir une vitesse de ventilation lev e Moyenne ou Basse R glez la vitesse du ventilateur sur lev e pour une limination maximale de l humidit Une fois que l humidit a t r duite et qu un fonctionnem...

Page 14: ...excessive REMARQUE Eloignez le d shumidificateur de la s cheuse Utilisez le d shumidificateur pour viter les dommages dus l humidit dans toutes les pi ces o des livres ou des objets de valeurs sont r...

Page 15: ...eil 2 Ouvrez le couvercle d vacuation sur le c t de l appareil 3 Fixez le tuyau d arrosage non fourni coup la longueur ad quate la buse et placez son extr mit au niveau du siphon de sol 4 Remettez le...

Page 16: ...Filtre Air Le filtre air derri re la grille avant doit tre v rifi et nettoy au bout de 250 heures de fonctionnement ou plus souvent si n cessaire Apr s 250 heures de fonctionnement le voyant Clean the...

Page 17: ...faible ou sur CO en continu pour une d shumidification maximale Les fen tres et les portes ne V rifiez que toutes les portes fen tres et autres sont peut tre pas ferm es ouvertures sont correctement...

Page 18: ...ur conna tre vos droits juridiques veuillez consulter le bureau local ou le bureau d tat des affaires aux consommateurs ou le Procureur G n ral de votre tat Exclusion des garanties tacites Sauf si ell...

Page 19: ...ctromenagersge ca Ceux qui d sirent r parer eux m mes leurs lectrom nagers peuvent recevoir pi ces et accessoires directement la maison cartes VISA MasterCard et Discover accept es Les proc dures expl...

Page 20: ...Soluci n de problemas 27 Ayuda al cliente Ayuda al cliente 31 Garant a 28 Producto con la etiqueta ENERGY STAR Como un asociado de ENERGY STAR GE ha determinado que este producto cumple con las gu as...

Page 21: ...ado debe reemplazar el recept culo Apague el control y desenchufe su deshumedificador antes de hacer cualquier reparaci n o limpiar GE no est no apoya que se le proporcione ning n servicio al deshumed...

Page 22: ...ado por uno de tres tomas con conexi n a tierra El deshumedificador deber a siempre estar conectado a un tomacorriente individual con su circuito de voltaje correspondiente Esto proporciona el mayor r...

Page 23: ...ventilador en alta High medio Medium o bajo Low Coloque el control del ventilador a alta High velocidad para lograr remover la mayor cantidad de humedad Cuando la humedad haya sido reducida y usted pr...

Page 24: ...d excesiva NOTA Coloque el deshumedificador lejos la secadora de ropa Use el deshumedificador para evitar da os causados por la humedad en lugares donde guarde libros o art culos de valor Use el deshu...

Page 25: ...ua caer al piso en lugar de caer dentro del tanque NOTAS No retire el balde con el deshumedificador en funcionamiento o si reci n se apag Esto puede hacer que el agua gotee del recipiente de drenaje E...

Page 26: ...bien sujeto para que el deshumedificador funcione Filtro de aire El filtro de aire detr s de la rejilla frontal debe inspeccionarse y limpiarse por lo menos cada 250 horas o m s a menudo si fuese nec...

Page 27: ...entual m s bajo o en CO continuo suficientemente bajo para obtener una m xima deshumidificaci n Las puertas y ventanas no Revise que todas las puertas ventanas y otras aberturas est n cerradas complet...

Page 28: ...asuntos del consumidor local o la oficina del Attorney General en su localidad Exclusi n de garant as implicadas Excepto donde est prohibido o restringido por la ley no hay garant as expresas orales...

Page 29: ...29 Notas ge com...

Page 30: ...30 Notas Ayuda al cliente Soluci n de problemas Operaci n Seguridad Cuidado y limpieza...

Page 31: ...tades auditivas favor de llamar al 800 TDD GEAC 800 833 4322 Piezas y accesorios ge com Aquellos individuos con la calificaci n necesaria para reparar sus propios electrodom sticos pueden pedir que se...

Page 32: ...isabilities check out our Website today For the hearing impaired please call 800 TDD GEAC 800 833 4322 Parts and Accessories ge com Individuals qualified to service their own appliances can have parts...

Reviews: