Masoneilan SVI FF Instruction Manual
=
|
17
© 2019 Baker Hughes, a GE company, LLC. All rights reserved.
Continuous Diagnostics
Alerts
Most systems monitor block errors and these can be linked for alert reporting in the DCS. See
Table 31 on page 149 for a full list of Transducer blocks parameters used for configuration.
Also see “Continuous Valve Diagnostics Concept” on page 231 for an in depth discussions of
this topic.
Alert configuration is available for the following areas:
Deviation alerts: You can configure a Deviation Value, a Position Error (Alert Point), a
Deadband around the Position Error and a Time before the alert is set. Active and
historical alerts are indicated.
HI, HI HI, LO and LO LO Alerts (): You can configure a desired Position, an Alert Point,
and a Deadband around the Alert Point. Active and historical alerts are indicated.
Near Closed Alert: You can configure a desired Position Closed value and an Alert Point
in hours after which the alert is set. Active and historical alerts are indicated.
Setpoint Timeout Alert: You can configure a desired Alert Point and Maximal Detect
Time. Active and historical alerts are indicated.
Pressure Alarms for HI, LO and LO LO: You can configure a desired Position, an Alert
Point, and a Deadband around the Alert Point. Active and historical alerts are
indicated.
Temperature Alarms for HI and LO: You can configure a desired Position, an Alert Point,
and a Deadband around the Alert Point. Active and historical alerts are indicated.
IP Output Alarms for HI and LO: You can configure a desired Position, an Alert Point,
and a Deadband around the Alert Point. Active and historical alerts are indicated.
Travel Alerts: You can configure two sets of travel accumulation alarms based on an
Alert Point and a Deadband. Active and historical alerts are indicated.
Counter Alerts: You can configure two sets of cycle counter accumulation alarms
based on an Alert Point and a Deadband. Active and historical alerts are indicated.
Operating Time Alerts: You can configure an operating time alarms based on an Alert
Time. Active and historical alerts are indicated.
Summary of Contents for Baker Hughes Masoneilan SVI FF
Page 12: ...This page intentionally left blank ...
Page 72: ...This page intentionally left blank ...
Page 82: ...This page intentionally left blank ...
Page 94: ...This page intentionally left blank ...
Page 108: ...This page intentionally left blank ...
Page 198: ...This page intentionally left blank ...
Page 206: ...This page intentionally left blank ...
Page 224: ...This page intentionally left blank ...
Page 228: ...This page intentionally left blank ...
Page 230: ...This page intentionally left blank ...
Page 250: ...This page intentionally left blank ...
Page 262: ...This page intentionally left blank ...
Page 263: ......