Design Guide
3
36" Frame to
Frame Width
*84" From
Floor to
Top Frame
35"
Case Width
*83-1/2"
at
Rear
25-3/8" Framed Models
25-3/4" Stainless Steel Models
Case Depth
Depth Including Handles:
26-7/8" Framed Models
27-3/4" Stainless Steel Models
28-11/16" Professional Models
THE INSTALLATION SPACE
Water And Electrical Locations
Electrical and water supply must be located as shown.
The Cutout Depth Must Be 24" Minimum
The unit will project forward, slightly beyond adjacent
cabinetry, depending on your installation.
Cutout Depth Beneath a Soffit:
When installed beneathh a soffit, the soffit cannot
exceed the 24" installation depth shown. The top case
trim overlaps the bottom of the soffit.
Additional Specifications
• A 115 volt 60Hz., 15 or 20 amp power supply
is required. An individual properly grounded branch
circuit or circuit breaker is recommended. Install
a properly grounded 3-prong electrical receptacle
recessed into the back wall. Electrical must be
located on rear wall as shown.
Note:
GFI (ground fault interrupter) is not
recommended.
• Water line can enter the opening through the
floor or back wall. The water line should be 1/4" O.D.
copper tubing or GE QuickConnect
™
kit between the
cold water line and water connection location, long
enough to extend to the front of the unit. Installation
of an easily accessible shut-off valve in the water line
is required.
DIMENSIONS AND CLEARANCES
* Shipping height. The
product can be adjusted
to fit into a cutout that
is 83-1/2" min. to 84-1/2"
max. height. Note that
the top case trim
at the front is 1/2" higher
and will overlap upper
cabinetry or soffit. Use
leveling legs and wheels
for a maximum 1" height
adjustment.
Product Clearances
These units are equipped with a 2-position door stop.
The factory set 130° door swing can be adjusted to 90°
if clearance to adjacent cabinets or walls is restricted.
Order WX14X99 door stop for precise settings between
90° and 130°.
130° Door Swing
90° Door Swing
25"
Minimum
to Wall
130
°
The finished
cutout width
must be
35-1/2".
Allow 25" minimum clearance for a full
130° door swing. Allow 15" for pan removal.
For a 90° door swing, allow 4" minimum clearance
to a wall for framed and stainless steel models.
Allow 5" minimum clearance for professional models.
If the 90° doorstop position is used, pan access
is maintained but pan removal is restricted.
See illustrations pages 5 and 6 to determine door swing
interaction with adjacent cabinets or countertops.
*
4
"
stainless and trimmed models.
5
"
Pro models.