Training Bulletin

TB17-18

August 2018

Front Control Gas Ranges

1

continued…

Bake and Broil operations shut down when temperature reaches 
approximately 250F.

If the selected bake or broil function operates briefly, then shuts down, the problem is not likely 
with the ERC.   A problem may exist with the cooling blower motor or the motor wiring.

Models affected:

C2S995SEL, PGS960BEL, PGS960EEL, PGS960FEL, PGS960SEL, 
CGS995EEL, CGS995SEL

Serial numbers:  

All

Repair Procedure:

1.

Cycle power to range.  Press and hold ‘2’ and ‘Bake’ simultaneously for three seconds to 
enter Fault Retrieval Mode.  Press ‘1’ to display stored faults.  Fault code F350 or F352 

will likely be displayed.  This indicates the ERC has detected that the cooling fan blower 
wheel is not turning, or turning too slowly.

2.

Enter the ERC’s Test Mode by pressing and holding ‘1’ and ‘Bake’ for three seconds.  
Pulse the cooling blower at low speed by pressing ‘3’.  If blower wheel, which is visible 

through the vent trim at rear of maintop, fails to turn, service is required.

3.

DISCONNECT POWER

. (LOTO) Remove:

Grates and top burners 

Rear spacer-to-wall trim

RJ45 connector from square hole
in upper corner of rear wire cover 
with a flat screwdriver

Backguard complement strip and 
upper rear wire cover

Vent trim

Maintop

Fan motor spill guard to access the motor’s electrical connections (see picture 

above)  

Summary of Contents for C2S995SEL

Page 1: ...al Mode Press 1 to display stored faults Fault code F350 or F352 will likely be displayed This indicates the ERC has detected that the cooling fan blower wheel is not turning or turning too slowly 2 Enter the ERC s Test Mode by pressing and holding 1 and Bake for three seconds Pulse the cooling blower at low speed by pressing 3 If blower wheel which is visible through the vent trim at rear of main...

Page 2: ...on Be sure nothing is pressing against the red hub on the end opposite the motor Re route any wires such as the RJ45 connector leads that may lie in contact with the motor shaft 5 Visually check wire connections to the low speed black wire and high speed red wire tabs of the blower motor Check connection to the Neutral white wire tab Make sure the gray plastic six pin connector is fully engaged 6 ...

Page 3: ...SS WB27X29499 CGS995EEL1DS CGS995SEL1SS WB27X29500 CHS995SEL1SS WB27X29501 8 If line voltage is present the BLOWER TANGENTIAL WB26X29060 will have to be replaced Normally the green sensor circuit board attached to blower motor will be good and can be reused 9 DISCONNECT POWER Loosen the upper rear splash guard Remove the three Hex head screws circled below to loosen side panel 10 Disconnect three ...

Page 4: ...ng the hex head screws in the order indicated in the photo above 12 Power up unit Check for blower operation as per Step 2 DISCONNECT POWER 13 Replace Hex head screws in side panel and the Phillips screws in rear splash guard Motor spill guard Maintop Vent trim RJ45 connector to square hole of rear wire cover Backguard complement strip and rear wire cover Rear spacer to wall trim Top burners and g...

Reviews: