background image

2

continued…

Ensure that proper clearance 
between wires and blower 
assembly will be maintained 
when rear wire cover is re-
installed.

Remove the three hex screws 
securing blower and lift blower 
and duct assembly.  Push 
insulation beyond vertical 
flange of oven cavity. 

4. Check for foreign objects in the blower wheel.  The wheel should rotate freely by hand 

without noise or undue friction.  Be sure nothing is pressing against the red hub on the 
end opposite the motor.  Re-route any wires, such as the RJ45 connector leads, that may 
lie in contact with the motor shaft.

5. Visually check wire connections to the low speed (black wire) and high speed (red wire) 

tabs of the blower motor.  Check connection to the Neutral (white wire) tab.  Make sure the 
gray plastic six-pin connector is fully engaged.

6. Power up range.  Check for blower operation again using Test Mode (Step 2).  If blower 

now operates, look for insulation pushing up on blower that would cause binding when fully 
assembled.

Summary of Contents for C2S995SEL

Page 1: ...al Mode Press 1 to display stored faults Fault code F350 or F352 will likely be displayed This indicates the ERC has detected that the cooling fan blower wheel is not turning or turning too slowly 2 Enter the ERC s Test Mode by pressing and holding 1 and Bake for three seconds Pulse the cooling blower at low speed by pressing 3 If blower wheel which is visible through the vent trim at rear of main...

Page 2: ...on Be sure nothing is pressing against the red hub on the end opposite the motor Re route any wires such as the RJ45 connector leads that may lie in contact with the motor shaft 5 Visually check wire connections to the low speed black wire and high speed red wire tabs of the blower motor Check connection to the Neutral white wire tab Make sure the gray plastic six pin connector is fully engaged 6 ...

Page 3: ...SS WB27X29499 CGS995EEL1DS CGS995SEL1SS WB27X29500 CHS995SEL1SS WB27X29501 8 If line voltage is present the BLOWER TANGENTIAL WB26X29060 will have to be replaced Normally the green sensor circuit board attached to blower motor will be good and can be reused 9 DISCONNECT POWER Loosen the upper rear splash guard Remove the three Hex head screws circled below to loosen side panel 10 Disconnect three ...

Page 4: ...ng the hex head screws in the order indicated in the photo above 12 Power up unit Check for blower operation as per Step 2 DISCONNECT POWER 13 Replace Hex head screws in side panel and the Phillips screws in rear splash guard Motor spill guard Maintop Vent trim RJ45 connector to square hole of rear wire cover Backguard complement strip and rear wire cover Rear spacer to wall trim Top burners and g...