Air direction

Air direction on the indoor side is

through the front grille and out the
top. Air flow out the top should not
be obstructed by curtains or drapes.

ROOMSIDE VIEW

Air direction on the outdoor side
is through the rear grille and out
through the top and side louvers.

Care and 

USER 
INSTRUCTIONS

Turn air conditioner off and
remove plug from wall receptacle
before cleaning.

Grilles & Cabinet

Wipe grilles with a clean cloth
lightly dampened with mild liquid

 detergent. Wash

cabinet with mild soap or detergent
and lukewarm water.

Condenser Coils

These coils on the weather side
of the unit should be checked
periodically and cleaned if clogged
with dirt or soot from the atmosphere.
If extremely soiled, they may need

to be steam cleaned, a service
available through your 
service outlet.

Air Filter

The foam air filter behind the
inlet grille should be washed at
least every 30 days or as often as
it needs cleaning.

Remove the inlet 

 by grasping

the tab at the top of the grille, pulling
out and lifting grille out.

 the grille on a flat surface

and remove the filter. Wash the
filter in hot, soapy water, just as
you would a sponge. Squeeze dry.

To reinstall the filter, place it on
pins located on the back side of
the grille.

To replace the grille, place the two
tabs at the bottom of the grille into
slots on the case and push the grille
forward.

5

Summary of Contents for Carry Cool ATL04

Page 1: ...ion 2 Safety Instructions 2 Care and Cleaning 5 User Maintenance Instructions 5 Condenser Coils 5 Warranty Back Cover Consumer Services 11 Control Settings 4 5 Electrical Requirements 3 Energy Saving Tips 6 Extension Cords 3 Grille and Cabinet 5 Grounding 3 GEAmwer Ceti Installation Instructions 7 8D 6262660 Carq Cool Models ATL04 ATL05 GEAppiances ...

Page 2: ...This air conditioner must be properly installed in accordance with the Installation Instructions before it is used See grounding instructions on page 3 Never unplug your air conditioner by pulling on the power cord Always grip plug firmly and pull straight out from the receptacle Repair or replace immediately all electric service cords that have become frayed or otherwise damaged Do not use a cord...

Page 3: ...UL listed adapter Fig 2 available at most local hardware stores TEMPORARY METHOD PERM T INCANADA ADAPTER PLUGS NOT The larger slot in the adapter must be aligned with the larger slot in the wdl outlet to provide proper polarity in the connection of the power cord ON Attaching an adapter ground terminal to wall outlet cover screw does not ground appliance unless cover screw is metal and not insulat...

Page 4: ...ieter operation 1 Set Selector Switch at LO COOL 2 Set Temperature Control at desired number When the Temperature Control is set on 7 or 8 and the Fan is set on low speed moisture may freeze on the coils and prevent the unit from cooling If this happens set the Fan at high speed and set the Temperature Control to a lower number For air circulation and filteriW without cooliW Set the Selector Switc...

Page 5: ...n the weather side of the unit should be checked periodically and cleaned if clogged with dirt or soot from the atmosphere If extremely soiled they may need to be steam cleaned a service available through your Hotpoint service outlet Air Filter The foam air filter behind the inlet grille should be washed at least every 30 days or as often as it needs cleaning Remove the inlet grille by grasping th...

Page 6: ...um cleaner or furniture If plugged in fuse could have blown or circuit breaker may have tripped Curtain blinds or furniture blocking the front of the air conditioner will restrict air flow Temperature Control may not be set high enough Turn knob to a higher number Highest setting should provide maximum cooling Air filter dirty should be cleaned at least every 30 days See instructions on page 5 Roo...

Page 7: ...60 Hz and connected to an individual properly grounded branch circuit protected by a 15 or 20 amp circuit breaker or time delay fuse If the electric supply provided does not meet the above specifi tions call a licensed electrician Aluminum house wiring may pose special problems consult a qualified electrician WINDOW REQUIREMEN Standard double hung window with actual opening width of 221 2 to 36 Cl...

Page 8: ...t touch stool with unit in verti l position reach around side of air conditioner and adjust bolt downward until it touches stool III Ill II 1 N E When air conditioner is removed from window leveling bolt should be adjusted above bottom surface of air conditioner 4 Cut a 5 piece off the foam sash gap gasket Tilt unit slightly to the inside and install gasket in channel directly behind opening in ha...

Page 9: ... channels to stool 4 Close curtains KEEPING A FIRM GRIP ON AIR CONDITIONER raise sash and carefully rock air conditioner backward and drain major portion of water in base of unit Care should be taken in lifting unit from window to avoid spilling any remaining water 5 Store parts for reuse along with air conditioner SPECIAL INSTALLATION 1 For windows from 36 to 49 in width order an extra wide kit R...

Page 10: ...10 ...

Page 11: ...ailable to help Your cdl and your question will be answered promptiy and courteously And you can cdl any time GE Answer erlte service is open 24 hours a day 7 days a week Parts andAccessories 800 626 2002 Individu qudKled to service their own appliances can have needed parts or accessories sent directiy to their h mle free of shipping charge The 1E parts system provides access to over 47 000 parts...

Page 12: ...C COMPANY GENERAL ELECTRIC FACTORY SERVICE GENERAL ELECTRIC HOTPOINT FACTORY SERVICE or GENERAL ELECTRIC CUSTOMER CARE SERVICE WHAT IS NOT COVERED Service trips to teach you how to use the product Read your Use and Care material If you then have any questions about operating the product please contact your dealer or our Consumer Affairs office at the address below or call toll free GE Answer Cente...

Reviews: