background image

EXHAUSTING THE DRYER (cont.)

Installation Instructions

BEFORE YOU BEGIN

 

Remove and discard existing plastic or metal foil 

duct and replace with UL-listed duct.

 

Remove any lint from the wall exhaust opening.

Internal 

Duct 

Opening

Wall

Check that exhaust 

hood damper opens 

and closes freely.

STANDARD REAR EXHAUST

We recommend that you install your dryer before 

installing your washer. This will permit direct 

access for easier exhaust connection.

Slide the end of the exhaust duct on the back of the 

dryer and secure with duct tape or a duct clamp.

NOTE:

 We strongly recommend using rigid metal 

exhaust duct. However, if flexible ducting is used it 

must be UL-Listed metal, not plastic. 

 

For straight-line installation, connect the dryer 

exhaust to the wall, using duct tape or a duct 

clamp.

RECOMMENDED CONFIGURATION TO 

MINIMIZE EXHAUST BLOCKAGE

Using duct elbows will prevent duct kinking and 

collapsing.

Transition 

Ducting

10

EXHAUST SYSTEM CHECKLIST

HOOD OR WALL CAP

 

Terminate in a manner to prevent back drafts or entry 

of birds or other wildlife.

 

Termination should present minimal resistance to 

the exhaust airflow and should require little or no 

maintenance to prevent clogging.

 

Wall caps must be installed at least 12” above ground 

level or any other obstruction with the opening 

pointed down.

SEPARATION OF TURNS

 

For best performance, separate all turns by at least 

4 ft. of straight duct, including distance between last 

turn and dampened wall cap. 

SEALING OF JOINTS

 

All joints should be tight to avoid leaks. The male end 

of each section of duct must point away from the 

dryer.

 

Duct joints should be made air- and moisture-tight 

by wrapping the overlapped joints with duct tape or 

aluminum tape.

 

Do not assemble ductwork with any fasteners 

that extend into the duct. These fasteners can 

accumulate lint, creating a potential fire hazard.

 

Horizontal runs should slope down towards the 

outdoors 1/4” per foot.

 

Provide an access for inspection and cleaning of 

the exhaust system, especially at turns and joints. 

Exhaust system shall be inspected and cleaned at 

least once a year.

INSULATION

 

Ductwork that runs through an unheated area or is 

near air conditioning should be insulated to reduce 

condensation and lint buildup.

DUCT TAPE OR

DUCT CLAM

P

DUCT TAPE OR

DUCT CLAM

P

4" METAL DUCT CU

T

TO PROPER LENGTH

EXTERNAL DUCT

OPENING

Summary of Contents for CleanSpeak GTD81ESPJMC

Page 1: ...yer installation must be performed by a qualified installer Install the clothes dryer according to these instructions and local codes DO NOT install a clothes dryer with flexible plastic venting mater...

Page 2: ...Parts com 24 hours a day or by phone at 800 626 2002 during normal business hours Part Number Accessory WE25X20060 Complete kit hoses Y adapter washers included OR WE1M847 Long hose and WE01X22395 Sho...

Page 3: ...st vent Provide an opening with a free area of at least 25 square inches for introduction of outside air into the dryer room See the sections for electrical connection information If the dryer is appr...

Page 4: ...5 Ensure the rubber flat washer is in place and attach the dryer s long inlet hose to one male end of the Y connector Tighten by hand until firmly seated 6 Ensure the rubber flat washer is in place a...

Page 5: ...TERMINAL BLOCK Slip joint pliers Flat blade crewdriver Phillips screwdriver Level TOOLS YOU WILL NEED MATERIALS YOU WILL NEED 4 dia metal elbow 3 4 strain relief UL recognized 4 duct clamps 2 or 4 spr...

Page 6: ...ire or electrical shock GROUNDING INSTRUCTIONS For a grounded cord connected dryer This dryer must be grounded In the event of a malfunction or breakdown grounding will reduce the risk of electric sho...

Page 7: ...d must also be used where local codes do not permit grounding through the neutral 3 wire connection is NOT for use on new construction 7 1 Turn off the circuit breaker s 30 amp or remove the dryer s c...

Page 8: ...ion duct maximizing drying performance Avoid resting the duct on sharp objects UL LISTED FLEXIBLE METAL FOIL TYPE TRANSITION DUCT In special installations it may be necessary to connect the dryer to t...

Page 9: ...th you must add all the straight portions and elbows of the system including the transition duct EXHAUST LENGTH 9 DO NOT bend or collapse ducting Use elbows if turns are necessary DO NOT use excessive...

Page 10: ...ld present minimal resistance to the exhaust airflow and should require little or no maintenance to prevent clogging Wall caps must be installed at least 12 above ground level or any other obstruction...

Page 11: ...Preassemble 4 elbow with 4 duct Wrap duct tape around joint Insert duct assembly elbow first through the side opening and connect the elbow to the dryer internal duct Be sure not to pull or damage th...

Page 12: ...fety hazard 12 DUCT TAPE ADDING ELBOW FOR EXHAUST THROUGH BOTTOM OF CABINET Insert the elbow through the rear opening and connect it to the dryer internal duct Apply duct tape as shown on the joint be...

Page 13: ...knife Small flat blade screwdriver Before you start Unplug the dryer from its electrical outlet 1 Open the door approximately 170 degrees With a putty knife remove the 4 plastic caps located along the...

Page 14: ...nstructions swapping left and right When you finish Plug the dryer back into its electrical outlet 5 Remove and swap the 2 cover caps and door handle from the outer door A Squeeze the tabs on the insi...

Page 15: ...io La instalaci n de la secadora debe efectuarla un instalador calificado Instale la secadora de ropa de acuerdo con estas instrucciones y en cumplimiento con los c digos locales NO instale una secado...

Page 16: ...EAppliancesparts com las 24 horas del d a o en forma telef nica llamando al 800 626 2002 durante el horario comercial habitual N mero de Pieza Accesorio WE25X20060 Kit completo mangueras lavadora con...

Page 17: ...greso de aire exterior dentro de la secadora habitaci n Para acceder a informaci n sobre la conexi n el ctrica consulte la section Si se aprob la instalaci n de su secadora en alcoba o armario esto fi...

Page 18: ...lugar y sujete la manguera larga de entrada de la secadora a un extremo macho del conector en Y Ajuste a mano hasta que est firmemente asentada 6 Aseg rese de que la arandela plana de goma se encuent...

Page 19: ...po de enchufe seg n el tomacorriente de la vivienda antes de comprar el cable 4 Placa de cubierta Kit WE1M454 C MO CONECTAR UNA SECADORA ELECTRICA S ltese si su secadora ya tiene un cable de alimentac...

Page 20: ...TRUCCIONES DE CONEXI N A TIERRA Para una secadora conectada con cable con conexi n a tierra Esta secadora deber estar conectado a tierra En caso de mal funcionamiento o aver a la conexi n a tierra red...

Page 21: ...NUNCA OLVIDE DE VOLVER A COLOCAR LA TAPA DEL BLOQUE TERMINAL NUNCA OLVIDE DE VOLVER A COLOCAR LA TAPA DEL BLOQUE TERMINAL 1 Desactive el disyuntor 30 amperios o quite el fusible del circuito de la sec...

Page 22: ...ber a se apoye sobre objetos cortantes CONDUCTO DE TRANSICI N DE METAL FLEXIBLE TIPO HOJA DE ALUMINIO DE LA LISTA DE UL En instalaciones especiales puede ser necesario conectar la secadora a la ventil...

Page 23: ...a longitud total del sistema de ventilaci n debe agregar todas las partes rectas y codos del sistema incluyendo el conducto de transici n LONGITUD DE SALIDA NO doble o pliegue los conductos Utilice co...

Page 24: ...istencia m nima al flujo de salida y debe requerir poco mantenimiento para evitar las obstrucciones Las cubiertas de pared deben instalarse por lo menos a 12 sobre el nivel del suelo o cualquier otra...

Page 25: ...incendio descarga el ctrica o laceraciones ADVERTENCIA Riesgo de incendio Gire la leng eta hasta 45 Porci n A Salida del lado izquierdo Orificio de montaje Vuelva a conectar la porci n cortada A del...

Page 26: ...Introduzca el codo a trav s de la abertura trasera y con ctelo al conducto interno de la secadora Aplique cinta aislante como puede verse en la junta entre el conducto interno de la secadora y el cod...

Page 27: ...Antes de Comenzar Desenchufe la secadora del tomacorriente 1 Abra la puerta aproximadamente 170 grados Con una esp tula retire las 4 tapas de pl stico ubicadas a lo largo del lado izquierdo del panel...

Page 28: ...enchufar la secadora en la salida el ctrica 5 Quite y cambie las 2 tapas y la jaladera de la puerta exterior A Apriete las pesta as de la parte interior de los clips de la jaladera de la puerta Empuj...

Reviews: