C-RS Ultrasonic Flow Transducer Installation Guide
15
5.4 The Single-Traverse Method - UCF (cont.)
11.
Wrap the chain on one small block around the pipe, and fasten the chain to the screw hook on the opposite side of
the block. Repeat this for the second short block.
Note:
Make sure the chains on both blocks are on the same side of the fixture and are on the opposite side from the
ruler.
12.
Tighten the pressure bolt all the way down on the short block that is
NOT
positioned over a crossmark. This will act
as a reminder that a transducer in
NOT
installed in that block.
13.
Use the screw hooks to tighten the chains on the fixed and adjustable short blocks until the blocks are secured
snugly to the pipe.
Note:
Make sure the chains are perpendicular to the clamping fixture and are not twisted. If the chains are slanted,
the fixture may move and this could change the final transducer spacing.
Top View