C-RS Ultrasonic Flow Transducer Installation Guide
41
6.9 Mounting Transducers into the MCF (cont.)
See typical completed
MCF
installations in
Figure 13
below.
WARNING! If your fixture is installed at an elevated location, GE recommends securing the fixture with the
optional safety chain or a tether/leash to prevent injury if the fixture falls off the pipe.
Figure 13: Completed MCF Installations with Transducers
WARNING! Before performing the next step make sure power to the flowmeter electronics has been
disconnected.
8.
Make the transducer cable connections as described in the flowmeter
User’s Manual
.
Double-Traverse Installation (Top View)
Single-Traverse Installation (Top View)