C-RS Ultrasonic Flow Transducer Installation Guide
43
6.11 Specifications
Table 4: C-RS Transducer Specifications
Parameter
Transducer #
401
402
403
Intended Uses
Large pipes
Ductile iron pipes
Lined pipes
Two-phase liquid
High performance
Mid-size pipes
High performance
Small pipes;
High performance
Installation Type
Clamp-on for liquid applications
Material
316 Stainless Steel or plastic
Pipe Sizes
2” to 300” (5 cm to 7.5 m)
diameter
2” to 300” (5 cm to 7.5 m)
diameter
2” to 6” (5 to 15 cm)
diameter
Operating Frequency
0.5 MHz
1.0 MHz
2.0 MHz
Electrical Rating
200 V peak-to-peak, 5 mA
Ambient Temperature Range -40 to +167°F (-40 to +75°C)
Process Temperature Range -40 to +302°F (-40 to +150°C)
North American Certification
- Explosion proof
Class I, Division 1, Group B, C & D
European Certification -
Flameproof
II 2 GD, EEx md IIC T6 80°C
Tam -40 to 75
o
C (-40 to 167
o
F)
KEMA 02ATEX2337 X
North American Certification
- Weatherproof
IP66, TYPE 4X
200Vpp, 5mA
European Certification
- Weatherproof
IP 66
IMPORTANT:
The transducer is protected by a suitable fuse located in the flowmeter electronics.
The fuse has a breaking capacity in accordance with the short circuit current of the supply.
Summary of Contents for CModel C-RS
Page 2: ......
Page 4: ...ii no content intended for this page ...
Page 52: ...44 C RS Ultrasonic Flow Transducer Installation Guide no content intended for this page ...
Page 56: ......