Electrical Requirements:

 240v/208v; 60Hz, 40A

Effective January 1, 1996, the National Electrical 
Code requires that new construction (not 
existing) utilize a 4-conductor connection to an 
electric range.

Receptacle Locations:

 Locally approved flexible 

service cord or conduit must be used because 
terminals are not accessible after range 
installation. See shaded area in drawing for 
location of electrical outlet box. Recommended 
outlet locations allow range to be installed 
directly against wall.

Note:

 30" ranges conform to U.L. requirements 

for 0" spacing from adjacent walls below 
countertops. To reduce possibility of scorching 
walls, engineering recommends a minimum of  
1-1/2" spacing to allow for possible extended, 
high-heat, no-load heating element operation.

Installation information:

 Before installing, 

consult installation instructions packed with 
product for current dimensional data.

All GE ranges are equipped with 

an Anti-Tip device. The installation 

of this device is an important, 

required step in the installation  

of the range.

Dimensions and Installation Information (in inches) 

CS980SN 

GE Café Free-Standing Radiant Range

 

30"

37-1/4"*

26-1/2"

46-3/4"

36-1/4"

+_

1/4

*41-1/4" with optional backguard kit

CENTER LINE

2-1/4

7-1/2

7-1/2

7

5

2-1/4

3-1/2

REAR

WALL

Receptacle locations:

 Locally approved flexible service cord or 

conduit must be used because terminals are not accessible after 
range installation. See shaded area in drawing for location of 
electrical outlet box. Recommended outlet locations allow range 
to be installed directly against wall.

Specification Created 8/08

221003

30"

37-1/4"*

26-1/2"

46-3/4"

36-1/4"

+_

1/4

*41-1/4" with optional backguard kit

CENTER LINE

2-1/4

7-1/2

7-1/2

7

5

2-1/4

3-1/2

REAR

WALL

Receptacle locations:

 Locally approved flexible service cord or 

conduit must be used because terminals are not accessible after 
range installation. See shaded area in drawing for location of 
electrical outlet box. Recommended outlet locations allow range 
to be installed directly against wall.