B-54
D30 Line Distance Protection System
GE Multilin
B.4 MEMORY MAPPING
APPENDIX B
B
BD70
...Repeated for Contact Input 79
BD78
...Repeated for Contact Input 80
BD80
...Repeated for Contact Input 81
BD88
...Repeated for Contact Input 82
BD90
...Repeated for Contact Input 83
BD98
...Repeated for Contact Input 84
BDA0
...Repeated for Contact Input 85
BDA8
...Repeated for Contact Input 86
BDB0
...Repeated for Contact Input 87
BDB8
...Repeated for Contact Input 88
BDC0
...Repeated for Contact Input 89
BDC8
...Repeated for Contact Input 90
BDD0
...Repeated for Contact Input 91
BDD8
...Repeated for Contact Input 92
BDE0
...Repeated for Contact Input 93
BDE8
...Repeated for Contact Input 94
BDF0
...Repeated for Contact Input 95
BDF8
...Repeated for Contact Input 96
Contact Input Thresholds (Read/Write Setting)
BE00
Contact Input
n
Threshold,
n
= 1 to 48 (48 items)
0 to 3
---
1
F128
1 (33 Vdc)
Virtual Inputs (Read/Write Setting) (64 modules)
BE30
Virtual Input 1 Function
0 to 1
---
1
F102
0 (Disabled)
BE31
Virtual Input 1 Name
---
---
---
F205
“Virt Ip 1“
BE37
Virtual Input 1 Programmed Type
0 to 1
---
1
F127
0 (Latched)
BE38
Virtual Input 1 Events
0 to 1
---
1
F102
0 (Disabled)
BE39
Reserved (3 items)
---
---
---
F001
0
BE3C
...Repeated for Virtual Input 2
BE48
...Repeated for Virtual Input 3
BE54
...Repeated for Virtual Input 4
BE60
...Repeated for Virtual Input 5
BE6C
...Repeated for Virtual Input 6
BE78
...Repeated for Virtual Input 7
BE84
...Repeated for Virtual Input 8
BE90
...Repeated for Virtual Input 9
BE9C
...Repeated for Virtual Input 10
BEA8
...Repeated for Virtual Input 11
BEB4
...Repeated for Virtual Input 12
BEC0
...Repeated for Virtual Input 13
BECC
...Repeated for Virtual Input 14
BED8
...Repeated for Virtual Input 15
BEE4
...Repeated for Virtual Input 16
BEF0
...Repeated for Virtual Input 17
BEFC
...Repeated for Virtual Input 18
BF08
...Repeated for Virtual Input 19
BF14
...Repeated for Virtual Input 20
BF20
...Repeated for Virtual Input 21
BF2C
...Repeated for Virtual Input 22
BF38
...Repeated for Virtual Input 23
BF44
...Repeated for Virtual Input 24
BF50
...Repeated for Virtual Input 25
BF5C
...Repeated for Virtual Input 26
BF68
...Repeated for Virtual Input 27
BF74
...Repeated for Virtual Input 28
BF80
...Repeated for Virtual Input 29
Table B–10: MODBUS MEMORY MAP (Sheet 46 of 58)
ADDR
REGISTER NAME
RANGE
UNITS
STEP
FORMAT
DEFAULT
Summary of Contents for D30D00HCHF8AH6AM6BP8BX7A
Page 10: ...x D30 Line Distance Protection System GE Multilin TABLE OF CONTENTS...
Page 374: ...5 248 D30 Line Distance Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5...
Page 398: ...6 24 D30 Line Distance Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6...
Page 410: ...7 12 D30 Line Distance Protection System GE Multilin 7 2 TARGETS 7 COMMANDS AND TARGETS 7...
Page 444: ...9 24 D30 Line Distance Protection System GE Multilin 9 5 FAULT LOCATOR 9 THEORY OF OPERATION 9...
Page 576: ...B 102 D30 Line Distance Protection System GE Multilin B 4 MEMORY MAPPING APPENDIX B B...
Page 616: ...D 10 D30 Line Distance Protection System GE Multilin D 1 IEC 60870 5 104 PROTOCOL APPENDIX D D...
Page 628: ...E 12 D30 Line Distance Protection System GE Multilin E 2 DNP POINT LISTS APPENDIX E E...
Page 636: ...F 8 D30 Line Distance Protection System GE Multilin F 3 WARRANTY APPENDIX F F...
Page 646: ...x D30 Line Distance Protection System GE Multilin INDEX...