B.4 MEMORY MAPPING
APPENDIX B
B
C60F
...Repeated for Direct Output 6
C612
...Repeated for Direct Output 7
C615
...Repeated for Direct Output 8
C618
...Repeated for Direct Output 9
C61B
...Repeated for Direct Output 10
C61E
...Repeated for Direct Output 11
C621
...Repeated for Direct Output 12
C624
...Repeated for Direct Output 13
C627
...Repeated for Direct Output 14
C62A
...Repeated for Direct Output 15
C62D
...Repeated for Direct Output 16
C630
...Repeated for Direct Output 17
C633
...Repeated for Direct Output 18
C636
...Repeated for Direct Output 19
C639
...Repeated for Direct Output 20
C63C
...Repeated for Direct Output 21
C63F
...Repeated for Direct Output 22
C642
...Repeated for Direct Output 23
C645
...Repeated for Direct Output 24
C648
...Repeated for Direct Output 25
C64B
...Repeated for Direct Output 26
C64E
...Repeated for Direct Output 27
C651
...Repeated for Direct Output 28
C654
...Repeated for Direct Output 29
C657
...Repeated for Direct Output 30
C65A
...Repeated for Direct Output 31
C65D
...Repeated for Direct Output 32
Reset (Read/Write Setting)
C750
FlexLogic operand which initiates a reset
0 to 4294967295
---
1
F300
0
Control Pushbuttons (Read/Write Setting) (7 modules)
C760
Control Pushbutton 1 Function
0 to 1
---
1
F102
0 (Disabled)
C761
Control Pushbutton 1 Events
0 to 1
---
1
F102
0 (Disabled)
C762
...Repeated for Control Pushbutton 2
C764
...Repeated for Control Pushbutton 3
C766
...Repeated for Control Pushbutton 4
C768
...Repeated for Control Pushbutton 5
C76A
...Repeated for Control Pushbutton 6
C76C
...Repeated for Control Pushbutton 7
Force Contact Inputs/Outputs (Read/Write Settings)
C7A0
Force Contact Input
x
State (96 items)
0 to 2
---
1
F144
0 (Disabled)
C800
Force Contact Output
x
State (64 items)
0 to 3
---
1
F131
0 (Disabled)
Direct Inputs/Outputs (Read/Write Setting)
C880
Direct Device ID
1 to 16
---
1
F001
1
C881
Direct I/O Channel 1 Ring Configuration Function
0 to 1
---
1
F126
0 (No)
C882
Platform Direct I/O Data Rate
64 to 128
kbps
64
F001
64
C883
Direct I/O Channel 2 Ring Configuration Function
0 to 1
---
1
F126
0 (No)
C884
Platform Direct I/O Crossover Function
0 to 1
---
1
F102
0 (Disabled)
Direct Input/Output Commands (Read/Write Command)
C888
Direct Input/Output Clear Counters Command
0 to 1
---
1
F126
0 (No)
Direct Inputs (Read/Write Setting) (32 modules)
C890
Direct Input 1 Device Number
0 to 16
---
1
F001
0
C891
Direct Input 1 Number
0 to 96
---
1
F001
0
C892
Direct Input 1 Default State
0 to 3
---
1
F086
0 (Off)
C893
Direct Input 1 Events
0 to 1
---
1
F102
0 (Disabled)
Table B–10: MODBUS MEMORY MAP (Sheet 50 of 58)
ADDR
REGISTER NAME
RANGE
UNITS
STEP
FORMAT
DEFAULT
Summary of Contents for D30D00HCHF8AH6AM6BP8BX7A
Page 10: ...x D30 Line Distance Protection System GE Multilin TABLE OF CONTENTS...
Page 374: ...5 248 D30 Line Distance Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5...
Page 398: ...6 24 D30 Line Distance Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6...
Page 410: ...7 12 D30 Line Distance Protection System GE Multilin 7 2 TARGETS 7 COMMANDS AND TARGETS 7...
Page 444: ...9 24 D30 Line Distance Protection System GE Multilin 9 5 FAULT LOCATOR 9 THEORY OF OPERATION 9...
Page 576: ...B 102 D30 Line Distance Protection System GE Multilin B 4 MEMORY MAPPING APPENDIX B B...
Page 616: ...D 10 D30 Line Distance Protection System GE Multilin D 1 IEC 60870 5 104 PROTOCOL APPENDIX D D...
Page 628: ...E 12 D30 Line Distance Protection System GE Multilin E 2 DNP POINT LISTS APPENDIX E E...
Page 636: ...F 8 D30 Line Distance Protection System GE Multilin F 3 WARRANTY APPENDIX F F...
Page 646: ...x D30 Line Distance Protection System GE Multilin INDEX...