B.4 MEMORY MAPPING
B
B236
...Repeated for Received Analog 20
B238
...Repeated for Received Analog 21
B23A
...Repeated for Received Analog 22
B23C
...Repeated for Received Analog 23
B23E
...Repeated for Received Analog 24
B240
...Repeated for Received Analog 25
B242
...Repeated for Received Analog 26
B244
...Repeated for Received Analog 27
B246
...Repeated for Received Analog 28
B248
...Repeated for Received Analog 29
B24A
...Repeated for Received Analog 30
B24C
...Repeated for Received Analog 31
B24E
...Repeated for Received Analog 32
IEC 61850 Configurable Report Settings (Read/Write Setting)
B290
IEC 61850 Configurable Reports Dataset Items (64 items)
0 to 848
---
1
F615
0 (None)
IEC 61850 XSWI Configuration (Read/Write Setting) (24 modules)
B370
FlexLogic Operand for IEC 61850 XSWI.ST.Loc Status
0 to 4294967295
---
1
F300
0
B373
...Repeated for module number 2
B376
...Repeated for module number 3
B379
...Repeated for module number 4
B37C
...Repeated for module number 5
B37F
...Repeated for module number 6
B382
...Repeated for module number 7
B385
...Repeated for module number 8
B388
...Repeated for module number 9
B38B
...Repeated for module number 10
B38E
...Repeated for module number 11
B391
...Repeated for module number 12
B394
...Repeated for module number 13
B397
...Repeated for module number 14
B39A
...Repeated for module number 15
B39D
...Repeated for module number 16
B3A0
...Repeated for module number 17
B3A3
...Repeated for module number 18
B3A6
...Repeated for module number 19
B3A9
...Repeated for module number 20
B3AC
...Repeated for module number 21
B3AF
...Repeated for module number 22
B3B2
...Repeated for module number 23
B3B5
...Repeated for module number 24
IEC 61850 XSWI Configuration (Read/Write Command) (24 modules)
B372
Command to Clear XSWI OpCnt (Operation Counter)
0 to 1
---
1
F126
0 (No)
IEC 61850 GGIO1 Configuration Settings (Read/Write Setting)
B400
Number of Status Indications in GGIO1
8 to 128
---
8
F001
8
B402
IEC 61850 GGIO1 Indication FlexLogic operands (128
items)
0 to 4294967295
---
1
F300
0
IEC 61850 Configurable GOOSE Transmission (Read/Write Setting) (8 modules)
B5A0
IEC 61850 Configurable GOOSE Function (GoEna)
0 to 1
---
1
F102
1 (Enabled)
B5A1
IEC 61850 Configurable GOOSE ID
---
---
---
F209
“GOOSEOut_x_”
B5C2
Configurable GOOSE Destination MAC Address
---
---
---
F072
0
B5C5
IEC 61850 Configurable GOOSE VLAN Transmit Priority
0 to 7
---
1
F001
4
B5C6
IEC 61850 Configurable GOOSE VLAN ID
0 to 4095
---
1
F001
0
B5C7
IEC 61850 Configurable GOOSE ETYPE APPID
0 to 16383
---
1
F001
0
B5C8
IEC 61850 Configurable GOOSE ConfRev (Configuration
Revision)
1 to 4294967295
---
1
F003
1
Table B–10: MODBUS MEMORY MAP (Sheet 43 of 58)
ADDR
REGISTER NAME
RANGE
UNITS
STEP
FORMAT
DEFAULT
Summary of Contents for D30D00HCHF8AH6AM6BP8BX7A
Page 10: ...x D30 Line Distance Protection System GE Multilin TABLE OF CONTENTS...
Page 374: ...5 248 D30 Line Distance Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5...
Page 398: ...6 24 D30 Line Distance Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6...
Page 410: ...7 12 D30 Line Distance Protection System GE Multilin 7 2 TARGETS 7 COMMANDS AND TARGETS 7...
Page 444: ...9 24 D30 Line Distance Protection System GE Multilin 9 5 FAULT LOCATOR 9 THEORY OF OPERATION 9...
Page 576: ...B 102 D30 Line Distance Protection System GE Multilin B 4 MEMORY MAPPING APPENDIX B B...
Page 616: ...D 10 D30 Line Distance Protection System GE Multilin D 1 IEC 60870 5 104 PROTOCOL APPENDIX D D...
Page 628: ...E 12 D30 Line Distance Protection System GE Multilin E 2 DNP POINT LISTS APPENDIX E E...
Page 636: ...F 8 D30 Line Distance Protection System GE Multilin F 3 WARRANTY APPENDIX F F...
Page 646: ...x D30 Line Distance Protection System GE Multilin INDEX...