background image

For answers to your Monogram,

® 

GE Profile

 or  

GE

®

 appliance questions, visit our website at 

ge.com or call GE Answer Center

®

 service,  

800.626.2000.

Specification Revised 10/07

360464

Listed by 

Underwriters 

Laboratories

Dimensions and Installation Information (in inches) 

Exhaust Options: 3-way via rear, left, and bottom.
Circuit Requirements: An individual, properly grounded 
branch circuit, protected by a 30-amp circuit breaker or 
a time-delay fuse, is required.
Note: Dryer wall outlet must be located within 36” 
of service cord entry and accessible when dryer is 
mounted in position.
Installation Information: For complete information, see 
installation instructions packed with your dryer.

27

1-5/8

41-1/2

31-1/8

5-1/2

3-3/4

Gas Dryer Rating

120V

60Hz, 6A

DCVH660GH 

GE

®

 7.0 Cu. Ft. Super Capacity Gas Dryer

 

Summary of Contents for DCVH660GH

Page 1: ...r left and bottom Circuit Requirements An individual properly grounded branch circuit protected by a 30 amp circuit breaker or a time delay fuse is required Note Dryer wall outlet must be located within 36 of service cord entry and accessible when dryer is mounted in position Installation Information For complete information see installation instructions packed with your dryer 27 1 5 8 41 1 2 31 1...

Page 2: ...buted If this closet contains both a washer and a dryer doors must contain a minimum of 120 sq in of open area equally distributed No other fuel burning appliance shall be installed in the same closet with a gas dryer Bathroom or Bedroom Installation The dryer MUST be exhausted to the outdoors The installation must conform with the local codes or in the absence of local codes with the National Fue...

Page 3: ...aution For personal safety do not terminate exhaust into a chimney under any enclosed house floor crawl space or into an attic since the accumulated lint could create a fire hazard or moisture could cause damage Never terminate the exhaust into a common duct or plenum with a kitchen exhaust since the combination of lint and grease could create a fire hazard Exhaust ducts should be terminated in a ...

Page 4: ...ered for quiet operation Adjustable End Of Cycle Signal Alerts you when cycle is done saving time between loads Multiple Dry Cycles Deliver optimal drying results Antibacterial Option Certified by the NSF to reduce up to 99 9 of certain types of bacteria Five Heat Selections Temperatures are matched to fabric type for better fabric care DuraDrum Provides long lasting dependability and durability M...