C.5.3b Pipe OD
4.
Click on the appropriate
Pipe OD Unit
type in the center pane from the list shown in Table 19. Then enter the
known pipe outside diameter or circumference in the right pane and click
[Next Item]
.
Obtain the required information by measuring either the pipe outside diameter (OD) or circumference at the transducer
installation site. The data may also be obtained from standard pipe size tables found in
Sound Speeds and Pipe Size
Data
(914-004).
5.
Enter the known
Pipe Wall Thickness
(in inches or mm) in the right pane and click
[Next Item].
C.5.3c Path and Axial Lengths
6.
Click on the appropriate
Path Length
unit type in the center pane. Then enter the path length of the ultrasonic signal
in the right pane and click
[Next Item].
Note:
If a spoolpiece was ordered with the meter, the transducer signal path length
(P)
and the transducer signal axial
length
(L)
are engraved on the flowcell and/or are included in the documentation supplied with the meter. For
on-site transducer installations, refer to Appendix C,
Measuring P and L Dimensions
, in the
Startup Guide
for
instructions.
7.
Click on the appropriate
Axial Length
unit type in the center pane. Then enter the axial length of the ultrasonic
signal in the right pane and click
[Next Item].
C.5.3d Fluid Type
8.
Double-click on the appropriate
Fluid Type
, either
Steam
or
Other
.
•
If you select
Other
, PanaView asks for the
Fluid Soundspeed
. Enter the appropriate soundspeed (in ft/sec) and
click
[Next Item].
C.5.3e Reynolds Correction
9.
Double-click on the appropriate choice to indicate whether you want
Reynolds Correction
.
•
If
Off
is selected, enter the
Calibration Factor
and click on
[Next Item].
•
If
On
is selected, enter the
Kinematic Viscosity
and click
[Next Item].
Then enter the
Calibration Factor
and click
[Next Item].
PanaView returns to the
Channel PROGRAM
menu. You have completed entering pipe parameters.
Table 19: Available Pipe OD Units
English
Metric
inches
mm
feet
meters
circum.in. = pipe circumference in inches
circum.mm = pipe circumference in millimeters
circum.ft = pipe circumference in feet
circum.m = pipe circumference in meters
Summary of Contents for DigitalFlow XGS868i
Page 2: ......
Page 4: ... no content intended for this page ...
Page 10: ...Contents viii DigitalFlow XGS868i Programming Manual ...
Page 52: ...Chapter 1 Programming Site Data 42 DigitalFlow XGS868i Programming Manual ...
Page 85: ...DigitalFlow XGS868i Programming Manual 75 Appendix A Menu Maps Appendix A Menu Maps ...
Page 86: ...76 DigitalFlow XGS868i Programming Manual no content intended for this page ...
Page 96: ...86 DigitalFlow XGS868i Programming Manual no content intended for this page ...
Page 146: ...Appendix C Programming the XGS868i Using PanaView 136 DigitalFlow XGS868i Programming Manual ...
Page 148: ...138 DigitalFlow XGS868i Programming Manual no content intended for this page ...
Page 174: ...Warranty 164 DigitalFlow XGS868i Programming Manual no content intended for this page ...
Page 175: ......