Appendix C. Programming the XGS868i Using PanaView™
C.5.4d Temperature Input
The XGS868i can use either a fixed temperature value or a live temperature input to calculate the density for the mass flow
rate display.
1.
Double-click on a
Fixed
temperature value or to set up the option card in
Slot 1
that will supply the live
temperature input and click
[Next Item].
Note:
If Slot 1 contains an activated option card with an analog input assigned to
Temperature
or an
RTD
input, Slot 1
appears as an option at the above prompt. If the process temperature is stable, a fixed value may be used, but
most applications require a live temperature input. If there is no active option card for temperature, the meter
assumes you are using a fixed temperature.
2.
Proceed to one of the following sections:
•
If you selected
Fixed
- proceed to Step 3.
•
If you selected
Slot 1
- proceed to Step 4.
3.
Enter the known
Fixed Temp.
(process temperature) and click
[Next Item].
The meter will accept values from
–328° to 1,832°F (–200° to 1,000°C). Proceed to
Base Temperature
below.
4.
Select
Input A
or
Input B
and click
[Next Item].
The inputs were labeled during setup.
Note:
The set up of Input A is used as an example. Identical procedures would be used to set up Input B.
C.5.4e Base Temperature
1.
Enter the
Base Temperature
and click
[Next Item].
The ratio of this value to the actual temperature is used to
calculate the standard mass flow rate.
2.
Do one of the following:
•
If you selected
Pressure
as the Input Type, proceed to
Pressure Input
on the next page.
•
If you selected
Temperature
as the Input Type, proceed to
Base Pressure
on the next page.
Summary of Contents for DigitalFlow XGS868i
Page 2: ......
Page 4: ... no content intended for this page ...
Page 10: ...Contents viii DigitalFlow XGS868i Programming Manual ...
Page 52: ...Chapter 1 Programming Site Data 42 DigitalFlow XGS868i Programming Manual ...
Page 85: ...DigitalFlow XGS868i Programming Manual 75 Appendix A Menu Maps Appendix A Menu Maps ...
Page 86: ...76 DigitalFlow XGS868i Programming Manual no content intended for this page ...
Page 96: ...86 DigitalFlow XGS868i Programming Manual no content intended for this page ...
Page 146: ...Appendix C Programming the XGS868i Using PanaView 136 DigitalFlow XGS868i Programming Manual ...
Page 148: ...138 DigitalFlow XGS868i Programming Manual no content intended for this page ...
Page 174: ...Warranty 164 DigitalFlow XGS868i Programming Manual no content intended for this page ...
Page 175: ......