Summary of Contents for DNCK440EA1WC

Page 1: ...50 F for satisfactory operation of the dryer control system NOTE Installation and service of this dryer requires basic mechanical and electrical skills It is your responsibility to contact a qualified installer to make the electrical connections I TOOLS YOU WILL NEED SLIP JOINT PLIERS _ FLAT BLADE SCREWDRIVER PHILLIPS SCREWDRIVER MATERIALS YOU WILL NEED 4 DIA METAL DUCT 4 RECOMMENDED DUCT CLAMPS 2...

Page 2: ...D OR AN ADAPTER PLUG WITH THIS APPLIANCE Dryer must be electrically grounded in accordance with local codes and ordinances or in the absence of local codes in accordance with the NATIONAL ELECTRI CAL CODE ANSI NFPA NO 70 ELECTRICAL REQUIREMENTS This dryer must be connected to an individual branch circuit protected by the required time delay fuses or circuit breakers A four or three wire single pha...

Page 3: ...XHAUST LENGTH TABLE Using exhaust longer than specified length will Increase the drying times and the energy cost Reduce the dryer life Accumulate lint creating a potential fire hazard The correct exhaust installation is YOUR RESPONSIBILITY Problems due to incorrect installation are not covered by the warranty The MAXIMUM ALLOWABLE length of the exhaust system depends upon the type of duct nmnber ...

Page 4: ...S READY FOR REAR EXHAUSTING IF SPACE IS LIMITED USE THE INSTRUCTIONS IN SECTION 9 TO EXHAUST DIRECTLY FROM THE SIDES OR BOTTOM OF THE CABINET STANDARD REAR EXHAUST Vented above floor level ELBOW HIGHLY RECOMMENDED ELBOW HIGHLY _ RECOMMENDED RECOMMENDED CONFIGURATION TO MINIMI7E EXHAUST BLOCKAGE NOTE ELBOWS WILL PREVENT DUCT KINKING AND COLLAPSING STANDARD REAR EXHAUST Vented at floor level FOR STR...

Page 5: ...TURE DAMAGE INCLUDING MOLD AND MILDEW ALCOVE OR CLOSET INSTALLATION If your dryer is approved for installation in an alcove or closet it will be stated on a label on the dryer back The dryer MUST be vented to the outdoors See the EXHAUST INFORMATION sections 3 4 Minimum clearance between dryer cabinet and adjacent walls or other surfaces is 0 in either side 3 in front and rear Minimum vertical spa...

Page 6: ...screwdriver 6 ADDING NEW DUCT FIXING HOLE _ PORTION A RIGHT OR LEFT SIDE EXHAUST Reconnect tile cut portion A of tile duct to tile blower housing Make sure that the shortened duct is aligned with the tab in tile base Use the screw saved previously to secure tile duct in place through the tab on tile appliance base ADDING ELBOW AND DUCT FOR EXHAUST TO LEFT OR RIGHT SIDE OF CABINET Preassemble 4 elb...

Page 7: ...ther hand holding the bottom remove the door from the dryer by lifting it UP and OUT 3 Rotate the door 180 Insert the door on the opposite side of the opening by moving the door IN and DOWN until the top hinge and the bottom hinge are resting on the top screws inserted in step 1 4 Remove the remaining screws from the side of the opening from which the door was removed With these screws secure each...

Page 8: ...Notes ...