GE Multilin
F60 Feeder Protection System
B-51
APPENDIX B
B.4 MEMORY MAPPING
B
BCF8
...Repeated for Contact Input 64
BD00
...Repeated for Contact Input 65
BD08
...Repeated for Contact Input 66
BD10
...Repeated for Contact Input 67
BD18
...Repeated for Contact Input 68
BD20
...Repeated for Contact Input 69
BD28
...Repeated for Contact Input 70
BD30
...Repeated for Contact Input 71
BD38
...Repeated for Contact Input 72
BD40
...Repeated for Contact Input 73
BD48
...Repeated for Contact Input 74
BD50
...Repeated for Contact Input 75
BD58
...Repeated for Contact Input 76
BD60
...Repeated for Contact Input 77
BD68
...Repeated for Contact Input 78
BD70
...Repeated for Contact Input 79
BD78
...Repeated for Contact Input 80
BD80
...Repeated for Contact Input 81
BD88
...Repeated for Contact Input 82
BD90
...Repeated for Contact Input 83
BD98
...Repeated for Contact Input 84
BDA0
...Repeated for Contact Input 85
BDA8
...Repeated for Contact Input 86
BDB0
...Repeated for Contact Input 87
BDB8
...Repeated for Contact Input 88
BDC0
...Repeated for Contact Input 89
BDC8
...Repeated for Contact Input 90
BDD0
...Repeated for Contact Input 91
BDD8
...Repeated for Contact Input 92
BDE0
...Repeated for Contact Input 93
BDE8
...Repeated for Contact Input 94
BDF0
...Repeated for Contact Input 95
BDF8
...Repeated for Contact Input 96
Contact Input Thresholds (Read/Write Setting)
BE00
Contact Input
n
Threshold,
n
= 1 to 24 (24 items)
0 to 3
---
1
F128
1 (33 Vdc)
Virtual Inputs (Read/Write Setting) (64 modules)
BE30
Virtual Input 1 Function
0 to 1
---
1
F102
0 (Disabled)
BE31
Virtual Input 1 Name
---
---
---
F205
“Virt Ip 1“
BE37
Virtual Input 1 Programmed Type
0 to 1
---
1
F127
0 (Latched)
BE38
Virtual Input 1 Events
0 to 1
---
1
F102
0 (Disabled)
BE39
Reserved (3 items)
---
---
---
F001
0
BE3C
...Repeated for Virtual Input 2
BE48
...Repeated for Virtual Input 3
BE54
...Repeated for Virtual Input 4
BE60
...Repeated for Virtual Input 5
BE6C
...Repeated for Virtual Input 6
BE78
...Repeated for Virtual Input 7
BE84
...Repeated for Virtual Input 8
BE90
...Repeated for Virtual Input 9
BE9C
...Repeated for Virtual Input 10
BEA8
...Repeated for Virtual Input 11
BEB4
...Repeated for Virtual Input 12
BEC0
...Repeated for Virtual Input 13
BECC
...Repeated for Virtual Input 14
Table B–9: MODBUS MEMORY MAP (Sheet 43 of 53)
ADDR
REGISTER NAME
RANGE
UNITS
STEP
FORMAT
DEFAULT
Summary of Contents for F60 UR Series
Page 2: ......
Page 4: ......
Page 30: ...1 20 F60 Feeder Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Page 48: ...2 18 F60 Feeder Protection System GE Multilin 2 2 SPECIFICATIONS 2 PRODUCT DESCRIPTION 2 ...
Page 126: ...4 30 F60 Feeder Protection System GE Multilin 4 2 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Page 354: ...5 228 F60 Feeder Protection System GE Multilin 5 9 TESTING 5 SETTINGS 5 ...
Page 382: ...6 28 F60 Feeder Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Page 398: ...8 8 F60 Feeder Protection System GE Multilin 8 2 FAULT LOCATOR 8 THEORY OF OPERATION 8 ...
Page 414: ...A 14 F60 Feeder Protection System GE Multilin A 1 PARAMETER LIST APPENDIXA A ...
Page 492: ...B 78 F60 Feeder Protection System GE Multilin B 4 MEMORY MAPPING APPENDIXB B ...
Page 530: ...D 10 F60 Feeder Protection System GE Multilin D 1 IEC 60870 5 104 APPENDIXD D ...
Page 542: ...E 12 F60 Feeder Protection System GE Multilin E 2 DNP POINT LISTS APPENDIXE E ...
Page 558: ...x F60 Feeder Protection System GE Multilin INDEX ...